When connecting to a battery, the terminal must be fused. The fuse
must fulfill the following values:
Current Rating:
Voltage:
NOTE
Interrupting Current: >= 1000 A
Fuse recommendation: Littlefuse FKS ATO 80V, Current Rating: 10 A
4.3 Connection programming
The main interfaces and the galvanically isolated power supply are under the cable duct cover on the rear of
the device.
Figure 3: Connection Ports, back of the device
Ethernet
(see 4.3.5)
So that IP protection of IP65 can be guaranteed for the connections, the
cable duct cover must be inserted and screwed on and the grommets
appropriate for the cross-section used. Feed-throughs not used must be
sealed with a grommet and blind plugs appropriate for the cross-
NOTE
section.
MFT10_Brief Overview_Resumen_breve_FCC_V1.00_en_es
10 A
>= 72 V
COM 1
(see 4.3.4/4.3.8)
(see 4.3.2/4.3.8)
USB 1
USB 2
(see 4.3.2/4.3.8)
Voltage supply
(see 4.3.1)
9 / 40