Fault
The convector
34
heater cannot be
switched off.
The convector
35
heater stops.
The convector
36
heater stops
burning. The reset
37
button lights up.
38
The convector
39
heater is producing
white smoke.
Burner
40
malfunction: the
indicator light (red)
is on.
The frequency
41
controller has a
fault: the indicator
light (red) is on.
Record the maintenance details in table A in the
appendix of this manual.
7
SPARE PARTS
Before use we advise you to have spare parts in
store, see table B in the appendix of this manual.
8
TECHNICAL INFORMATION
•
See for technical specifications table C in the
appendix of this manual.
9
INSTALLING ACCESSORIES
9.1
Flue (Fig. 4)
The convector heater has a flue connection.
1.
Slide a flue (B) over the connection (C).
Caution
The flue must be pointed upwards. Do
not let the flue point sideways. An angle
of 45° is acceptable; the length of the
flue should be at least 1000 mm.
2.
Place a rain cover (A) on the end of the flue.
IMAC
Cause
The magnet valve or valves will
not close.
An overheating problem has
occurred in the convector heater.
The fuel-supply line or the fuel
filter is leaking.
The protective grill of the air inlet
is dirty or clogged.
The heat exchanger is blocked.
There is air in the fuel system.
There is no fuel.
The photocell is dirty.
The photocell is defective.
The motor of the main fan has a
problem.
40.020.949 - rev. 05 - 2011
Solution
Close the cock, see fig. 8 (B).
Contact your dealer.
Reduce the resistance at the
outlet.
Reset the thermostat.
Contact the dealer if the error is
repeated.
Check and replace if necessary. User
Clean the grill.
Clean the heat exchanger.
Check the fuel-supply line for
leakage.
Check whether there is fuel in
the tank.
Clean the photocell.
Replace the photocell.
Reset the frequency controller:
press the button, see fig. 7 (G).
Contact the dealer if the error is
repeated.
9.2
Diameter of the flue
/i
Flue (external)
Diameter
9.3
Air hose
An air hose may be connected to the exhaust
opening of the convector heater in order to blow
hot air at a large distance from the convector
heater.
Caution
Check the temperature resistance of the
hose used.
Contact your dealer for information about the
maximum length of the exhaust hoses, bends,
manifolds and hose clamps.
9.4
Diameters of exhaust hoses
/i
Three-way outlet
Diameter
English
Action
User
Dealer
User
User
Dealer
User
Dealer
User
User
User
Dealer
User
Dealer
IMAC 4000
300 mm
IMAC 4000
500 mm
21