OPERATIONS
!
EXCEPT as otherwise specified by the manufacturer, this product is specifically designed for compressed
air service, and use with any other fluid (liquid or gas) is a misapplication. For example, use with or injection
of certain hazardous liquids or gases in the system (such as alcohol or liquid petroleum gas) could be harm-
ful to the unit or result in a combustible condition or hazardous external leakage. Manufacturer's warranties
are void in the event of misapplication, and manufacturer assumes no responsibility for any resulting loss.
Before using with fluids other than compressed air, or for nonindustrial applications, or for life support sys-
tems consult manufacturer for written approval.
ATTENTION: Make sure bowl is fully inserted into body, and then fully turned to lock bowl in place before apply-
ing air pressure to unit. When bowl is properly installed, the alignment markings on the bowl/bowlguard assem-
bly and the marks on the body will line up, indicating proper assembly. Failure to do so may cause air pressure
to blow bowl off of unit, resulting in serious personal injury or death.
INSTALLATION
1. Purge downstream air line of oil.
2. Install the unit with the air flowing in the direction indicated by
the arrow on the body and/or the DP2 Differential Pressure Indicator.
3. The drain line connection is dependent on the type of drain that
is selected.
4. Maximum inlet pressure and operating temperature ratings are:
units with DP2 150 psig (10,3 bar) 150°F (66°C); units without DP2:
300 psig (20 bar) 150°F (66°C).
NOTE: CONTAMINATES REMOVED FROM THE COMPRESSED AIR
SYSTEM MUST BE DISPOSED OF IN ACCORDANCE WITH
LOCAL, STATE AND FEDERAL STANDARDS.
MAINTENANCE
1. TO CLEAN OR REPLACE FILTER ELEMENT: Shut off air supply and
reduce pressure in the unit to zero, remove the 8 screws from the filter
housing, unscrew the filter support and remove filter element.
a. IF THE UNIT HAS A RIGID FILTER ELEMENT: remove and clean period-
ically by tapping on a hard surface, and blowing off with air gun. Torque
element support to 8 ± 1 ft. lb. when replacing element. Element should
be cleaned/replaced when the DP2 differential pressure indicator is
completely red.
2. IF THE UNIT HAS A MANUAL DRAIN, DRAIN THE UNIT ONCE EVERY
8 HOURS MINIMUM. To do so, rotate the drain knob to the left one or
two turns.* If the unit is equipped with an automatic drain, clean the
screen around the drain. Clean screen by blowing off with air gun.
3. When the bowl becomes dirty, clean with a dry clean cloth.
4. Before placing the unit in service, make sure that the bowl is properly
reinstalled, and securely bolted in place.
*NOTE: In the event the drain knob is over-rotated, it may become disen-
gaged from the drain stem. In such a case, pull down on both the
knob and the stem while rotating to the right to re-engage.
REPAIR KITS AND REPLACEMENT PARTS
Filter Element Kit (F35)
(includes filter element and o-rings) ............................................FRP-95-505
Filter Element Kit Type (F36)
(includes filter element and o-rings) ............................................FRP-95-506
Filter Element Kit Type (F37)
(includes filter element, o-ring) ....................................................FRP-95-507
Drain Plate Kits
Drain Plate (For use with internal Automatic Mechanical
float drain No. GRP-95-981 or GRP-96-300)......................GRP-95-391
Drain Plate (
/
NPT) .................................................................GRP-95-392
1
4
Drain Plate Rc
1
/
......................................................................GRP-95-394
4
1
Drain Plate (
/
NPT) .................................................................GRP-95-393
2
Drain Plate Rc
1
/
......................................................................GRP-95-395
2
Differential Pressure Indicator (Standard) .......................................DP2-01-001
Differential Pressure Removal Cap Kit ...........................................GRP-95-022
Bowl O-ring Kit ................................................................................GRP-95-291
Drains:
Internal Drains:
Automatic Mechanical Drain (Fluorocarbon
seals w/
1
/
NPT stem) ...........................................................GRP-95-981
8
Automatic Mechanical Drain (Fluorocarbon
seals w/R
1
/
stem)................................................................GRP-96-300
8
Manual Override for Auto Drain (GRP-95-981
External Drains:
External Automatic Mechanical Drain ......................................X01-04-000
External Automatic Mechanical Drain .......................................X02-04-F00
External Automatic Mechanical Drain.......................................XB3-04-000
(See reverse side for Repair and Replacement Parts cont.)
®
WARNING
!
1
/
NPT) ...........GRP-96-000
8
(GRP-96-300 R
1
/
) ................GRP-96-100
8
INSTALLATION AND
MAINTENANCE SHEET
Filter Models F35, F36 and F37
with Variations and Accessories
DP2 DIFFERENTIAL
PRESSURE
INDICATOR
O-RING
5 MICRON
ELEMENT
O-RING
NUT
(Torque 8 ± 1 FT.-LB.)
O-RING
DRAIN PLATE
SCREWS
(6 Required)
4—2
SCREW
(2 Required)
COVER
DEFLECTOR
VANE
STUD
BAFFLE
O-RING
METAL
BOWL
(1 Required)
SCREWS
(Torque 54 ± 2 FT.-LB.)
(8 Required)
AUTOMATIC
MECHANICAL
DRAIN (Optional)
O-RING
DRAIN PLATE
SCREWS
(16 ± 2 FT.-LB.)
(6 Required)
NUT
83-719-000 REV B 11/96
Printed in the U.S.A.
loading

Resumen de contenidos para Wilkerson F35

  • Página 1 INSTALLATION AND ® OPERATIONS MAINTENANCE SHEET Filter Models F35, F36 and F37 WARNING with Variations and Accessories EXCEPT as otherwise specified by the manufacturer, this product is specifically designed for compressed air service, and use with any other fluid (liquid or gas) is a misapplication. For example, use with or injection...
  • Página 2 REPAIR KITS AND REPLACEMENT PARTS Cont. Automatic Electric Drain Valve MODEL PORT ORIFICE OPERATING PRESS NUMBER KIT SIZE SIZE ELECTRICAL MIN. MAX. X20-02-ED00 115 VAC/1Ph/50-60Hz 2 psig 300 psig " " X20-02-EE00 " " 230 VAC/1PH/50-60Hz 2 psig 300 psig X20-02-EC00 24 VDC 5 psig...
  • Página 3 FICHE D’INSTALLATION ET ® OPERATIONS D’ENTRETIEN Filtres modèles F35, F36 et F37 AVERTISSEMENT avec variations et accessoires SAUF indication contraire du fabricant, le présent produit est spécifiquement conçu pour fonc- tionner à l’air comprimé et son utilisation avec tout autre fluide (liquide ou gazeux) constitue un INDICATEUR DE usage abusif.
  • Página 4 TROUSSES DE RÉPARATION ET PIÈCES DE RECHANGE (SUITE) Soupape de vidange automatique élctrique DIMENSIONS PRESSION DE FONCTIONNEMENT NUMÉRO DE MODÉLE DIMENSIONS CARACTÉRISTIQUES DE PORT DE L’ORIFICE DE TROUSSE ÉLECTRIQUES MINI MAXI X20-02-ED00 115 VAC/1Ph/50-60Hz 2 psig 300 psig " " X20-02-EE00 230 VAC/1PH/50-60Hz 2 psig...
  • Página 5: Instalacion

    HOJA DE INSTALACION Y ® OPERATIONS MANTENIMIENTO Filtros Modelos F35, F36 y F37 con ADVERTENCIA Variaciones y Accesorios SALVO que el fabricante especifique lo contrario, este producto está diseñado específicamente para el uso con aire comprimido, y su uso con cualquier otro fluido (líquido o gas) es una aplicación indebida. Por ejem- plo, el uso o la inyección de ciertos líquidos o gases peligrosos en el sistema (tales como el alcohol o...
  • Página 6 JUEGOS DE REPARACION Y REPUESTOS (Continuación) Válvula de drenaje eléctrico automático TAMAÑO DE TAMAÑO DE PRESION FUNCIONAL JUEGO MODELO ESPECIFICACIONES ABERTURA NUMERO ORIFICIO ELECTRICAS MIN. MAX. X20-02-ED00 115 VAC/1Ph/50-60Hz 2 psig 300 psig " " X20-02-EE00 230 VAC/1PH/50-60Hz 2 psig 300 psig "...

Este manual también es adecuado para:

F36F37