WARNING
!
To avoid unpredictable system behavior that can cause personal
injury and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
• Operate within the manufacturer's specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
CAUTION
!
Polycarbonate bowls, being transparent and tough, are ideal for use with
Filters and Lubricators. They are suitable for use in normal industrial
environments, but should not be located in areas where they could be
subjected to direct sunlight, an impact blow, nor temperatures outside of the
rated range. As with most plastics, some chemicals can cause damage.
Polycarbonate bowls should not be exposed to chlorinated hydrocarbons,
ketones, esters and certain alcohols. They should not be used in air systems
where compressors are lubricated with fire-resistant fluids such as phosphate
ester and di-ester types.
Metal bowls are recommended where ambient and/or media conditions are
not compatible with polycarbonate bowls. Metal bowls resist the action of
most such solvents, but should not be used where strong acids or bases are
present or in salt laden atmospheres. Consult the factory for specific
recommendations where these conditions exist.
TO CLEAN POLYCARBONATE BOWLS USE MILD SOAP AND WATER
ONLY! DO NOT use cleansing agents such as acetone, benzene, carbon
tetrachloride, gasoline, toluene, etc., which are damaging to this plastic.
Bowl guards are recommended for added protection of polycarbonate bowls
where chemical attack may occur.
WARNING
!
To avoid polycarbonate bowl rupture that can cause personal injury or
property damage, do not exceed bowl pressure or temperature ratings.
Polycarbonate bowls have a 150 psig (1030 kPa) pressure rating and a
maximum temperature rating of 52°C (125°F).
WARNING
!
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed maximum primary pressure rating.
Introduction
Follow these instructions when installing, operating, or servicing the product.
Application Limits
These products are intended for use in general purpose compressed air
systems only.
With Polycarbonate Bowl
Operating Pressure Maximum
Operating Temperature Maximum
Operating Temperature Minimum
Tel: (269) 629-5000
kPa
PSIG
bar
1034
150
10.3
52°C (125°F)
0°C (32°F)
Installation & Service Instructions
83-954-000
1/4" and 3/8"
B12 Filter / Regulator Series, and
T12 Precision Filter / Regulator
ISSUED: May, 2005
Supersedes: November, 2003
Doc.# 83954000, ECN# 050500, Rev. 5
With Metal Bowl
Operating Pressure Maximum
Operating Temperature Maximum
Operating Temperature Minimum
Note: The maximum recommended pressure drop for a particulate filter is
69 kPa (10 PSIG, 0.7 bar)
ANSI Symbol
Adjustable Filter / Regulator
with Manual Drain
Installation
1. The Filter / Regulator should be installed with reasonable accessibility for
service whenever possible – repair service kits are available. Keep pipe
or tubing lengths to a minimum with inside clean and free of dirt and
chips. Pipe joint compound should be used sparingly and applied only to
the male pipe – never into the female port. Do not use PTFE tape to seal
pipe joints – pieces have a tendency to break off and lodge inside the
unit, possibly causing malfunction. Also, new pipe or hose should be
installed between the Filter / Regulator and equipment being protected.
2. The upstream pipe work must be clear of accumulated dirt and liquids.
3. Select a Filter / Regulator location as close as possible to the equipment
being protected.
4. Install Filter / Regulator so that air flows in the direction of arrow on body.
5. Install Filter / Regulator vertically with the bowl drain mechanism at the
bottom. Free moisture will thus drain into the sump ("quiet zone") at the
bottom of the bowl.
6. Gauge ports are located on both sides of the Filter / Regulator body for
your convenience. It is necessary to install a gauge or socket pipe plugs
into each port during installation.
Operation
1. Both free moisture and solids are removed automatically by the filter.
2. Manual drain filters must be drained regularly before the separated
moisture and oil reaches the bottom of the baffle or end cap.
3. The filter element should be removed and replaced when pressure
differential across the filter is 69 kPa (10 psig).
4. Before turning on the air supply, turn the knob counterclockwise until
compression is released from the pressure control spring. Then turn knob
clockwise and adjust regulator to desired downstream pressure. This
permits pressure to build up slowly in the downstream line.
WARNING
!
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you
analyze all aspects of your application, including consequences of any
failure and review the information concerning the product or systems in the
current product catalog. Due to the variety of operating conditions and
applications for these products or systems, the user, through its own analysis
and testing, is solely responsible for making the final selection of the
products and systems and assuring that all performance, safety and warning
requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by
The Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.
kPa
PSIG
bar
1724
250
17.2
80°C (175°F)
0°C (32°F)
loading

Resumen de contenidos para Wilkerson B12 Serie

  • Página 1 Installation & Service Instructions 83-954-000 1/4" and 3/8" B12 Filter / Regulator Series, and Richland, MI 49083 Tel: (269) 629-5000 T12 Precision Filter / Regulator ISSUED: May, 2005 Supersedes: November, 2003 Doc.# 83954000, ECN# 050500, Rev. 5 With Metal Bowl WARNING PSIG Operating Pressure Maximum...
  • Página 2 1/4" and 3/8" B12 Filter / Regulator Series, and T12 Precision Filter Regulator 83-954-000 5. To decrease regulated pressure settings, always reset from a pressure Service lower than the final setting required. Example, lowering the secondary Caution: Disconnect or shut off air supply and exhaust the primary pressure from 550 to 410 kPa (80 to 60 psig) is best accomplished by and secondary pressures before servicing unit.
  • Página 3 Instructions d’installation et d’entretien 83-954-000 (French) Régulateur et filtre B12 et régulateur et filtre de précision T12 de 1/4 in et 3/8 in Richland, MI 49083 Tel: (269) 629-5000 PUBLICATION: mai, 2005 Remplace: novembre, 2003 AVERTISSEMENT Doc.# 83954000, ECN# 050500, Rev. 5 Afin d’éviter un fonctionnement imprévu du système pouvant occasionner des blessures aux personnes et des dommages matériels : Avec cuve métallique...
  • Página 4 Régulateur et filtre B12 et régulateur et filtre de précision T12 de 1/4 in et 3/8 in 83-954-000 5. Pour réduire la pression du système, il faut toujours faire le réglage à Entretien partir d’une pression plus basse que la valeur désirée. Par exemple, pour Attention –...
  • Página 5: Instalación

    Instrucciones para instalación y servicio 83-954-000 (Spanish) Filtros / reguladores serie B12 y filtros / reguladores de precisión T12 Richland, MI 49083 Tel: (269) 629-5000 de 1/4 y 3/8 de pulgada EMITIDO: Mayo de 2005 Sustituye a: Noviembre de 2003 ADVERTENCIA Doc.# 83954000, ECN# 050500, Rev.
  • Página 6 Filtros / reguladores serie B12 y filtros / reguladores de precisión T12 de 1/4 y 3/8 de pulgada 83-954-000 5. Para disminuir la graduación de la presión, comience siempre con una presión Servicio menor que la graduación final requerida. Por ejemplo, para reducir la presión Precaución: Antes de dar servicio a la unidad, desconecte o desactive secundaria de 550 a 410 kPa (80 a 60 psig) lo mejor es reducir la presión el suministro de aire y elimine la presión principal y secundaria.

Este manual también es adecuado para:

T12 serie