Safety Notes; Installation Instructions; Symbol Description - Hansgrohe 13439180 Instrucciones De Montaje

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• When installing the bath fitting set, it must be guar-
anteed, that each part can be within reached and if
necessary removed.To avoid damages of entering
water by the passage of the hose, the area under the
tub must be protected against leacking water.
• Do a leak test once a year.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Assembly see page 31

Symbol description

Do not use silicone containing acetic acid!
Dimensions (see page 34)
Spare parts (see page 35)
Special accessories (order as an
extra)
Secuflex Box #28389000 (see page 35)
Finish set (see page 36)
Tabla de contenido
loading

Tabla de contenido