Waiting Time; Electrical Connection - Haier HB16WMAA Manual De Usuario

Ocultar thumbs Ver también para HB16WMAA:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 146
10- Installation
10.7
2 h

10.8 Electrical connection

Before each connection check if:
power supply, socket and fusing are appropriate to the rating plate.
the power socket is earthed and no multi-plug or extension.
the power plug and socket are strictly according.
Connect the plug to a properly installed household socket.
WARNING!
To avoid risks a damaged power cord must be replaced by the customer service (see
warranty card).
When positioning the appliance, ensure the supply cord is not trapped or damaged.
Do not locate multiple portable socket-outlets or portable power supplies at the rear
of the appliance.
Taking care to avoid causing a fire by igniting flammable material.
- extended temperate: 'this refrigerating appliance is intended to be used at ambient
temperatures ranging from 10 °C to 32 °C';
-    temperate: 'this refrigerating appliance is intended to be used at ambient tempera-
tures ranging from 16 °C to 32 °C';
-    subtropical: 'this refrigerating appliance is intended to be used at ambient
temperatures ranging from 16 °C to 38 °C';
-    tropical: 'this refrigerating appliance is intended to be used at ambient tempera-
tures ranging from 16 °C to 43 °C';
32

10.7 Waiting time

To the maintenance-free lubrication oil is located in the
capsule of the compressor. This oil can get through
the closed pipe system during slanting transport. Be-
fore connecting the appliance to the power supply you
have to wait 2 hours (Fig. 10.7) so that the oil runs back
into the capsule.
GB
Tabla de contenido
loading

Este manual también es adecuado para:

Hb16wbaaHb16wsnaa

Tabla de contenido