4.2 Switching on the 30 Hz filter
4.3 Multitplying factor
4.4 Dividing factor
4.5 Decimal point
* where bounce occurs, e.g. with contacts
5
The filter provides input
damping*
30 Hz filter off (f max )
30 Hzfilter on
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
The decimal point defines
the resolution in the
selected measuring range
1/min or 1/sec
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
4.6 Display mode
4.7 Max. time to wait until „0" is displayed
This parameter indicates, how long it takes, when
measuring is active, until „0" is displayed.
4.8 End of programming
Value conversion and
display in 1/s
Value conversion and
display in 1/min
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.