2. Remove the terminal block cover to expose the
terminal block.
3. Remove the top nut (has an attached locking washer)
from each terminal post.
Note: DO NOT remove the second nut/washer on each
post. These must stay in place to anchor the internal
wiring attached to the terminal block.
4. Attach the white wire to the center junction block
terminal using one of the nut/washer parts.
5. Attach the red wire to the left junction block terminal
using one of the nut/washer parts removed in step 2.
6. Attach the black wire to the right junction block terminal
using one of the nut/washer parts.
7. Tighten all connections securely and replace terminal
block cover.
8.
Properly secure strain relief (see previous section).
Note: DO NOT plug in range at this time.

Connect Electric Flexible Conduit

The range can also be connected via flxible conduit. If
using this method, always use the lugs supplied
Note: In Canada, the range is shipped from the factory with
the range cord already installed. Continue to "Complete the
installation" on page 11. For installations other than those in
Canada, connect the flexible conduit at the terminal block.
Four Wire Flexible Conduit Connection
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. Remove the top nut (has an attached locking washer)
from each terminal post.
Note: DO NOT remove the second nut/washer on each
post. These must stay in place to anchor the internal wiring
attached to the terminal block.
4. Remove the green grounding screw from the lower end
of the grounding strap.
5. Remove the grounding strap from the center post on
the terminal block. The strap will not be needed with
the flexible conduit electric installation. Remove it from
the unit.
6. Attach one terminal lug (packaged with this manual)
using the green grounding screw. Insert the screw
through the lug into the grounding hole below the
terminal block. Tighten the screw firmly, but do not
overtighten.
7. Place one terminal lug (packaged with this manual) on
each terminal block post. Replace the nut/washer on
each post and tighten to 20 in/lbs. (50.8 cm) of torque.
8. Strip 3/8" (9.5 mm) of insulation from the end of the
insulated grounding wire.
English 12