Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Croma 100 Modo De Empleo

Ocultar thumbs Ver también para Croma 100:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch
sensitive body parts (such as your eyes). An
adequate distance must be kept between the shower
and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

The fitting must be installed, flushed and tested after
the valid norms.
The installation dimensions stated in this installation
instructions are ideal for people of approximately
1800 mm in body height. The dimensions can be
altered if required. In this case you will have to attend
to the minimum height of 2320 mm from shower tray
floor, and alter all the required measurements as
necessary.
Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels
are only suitable for concrete. For another wall
constructions the manufacturer's indications of the
dowel manufacturer have to be taken into account.
The premounted filter insert must be used to ensure
a normal flow of the shower and to prevent dirt from
entering through the pipes. Dirt entering can affect
the function and/or lead to damages to the shower.
HansGrohe will not be held liable for this type of
damage. (see page 63).
6
English
In case of emergencies, the lower part of the pipe can
be shortened by means of a fine saw.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
anti-pollution function

Symbol description

Do not use silicone containing acetic acid!
To adjust the hot water limiter on single lever
mixers, please see page 64. No adjustment
is necessary when using a continuous flow
water heater.
Dimensions (see page 67)

Flow diagram

(see page 68)
Operation (see page 69)
overhead shower
hand shower
max. 1 MPa
0,15 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
150 mm
cold right -
hot left
Tabla de contenido
loading

Este manual también es adecuado para:

2715400027155000

Tabla de contenido