1.
Determine the ceiling bracket
locations
Parallel layout
24"
P2
P2
48"
P2
P2
48"
2' x 4'
24"
48"
P2
P2
Perpendicular layout
24"
48"
P2
P2
26"
P2
P2
2' x 4'
48"
P2
P2
P2
The storage rack ceiling brackets can be positioned parallel
or perpendicular to the wood ceiling joists/rafters. Determine
the application required for your desired installation. If drywall
covers the joists, use a stud finder to determine the joist/rafter
locations and mark with masking tape. For applications requiring
installation of the brackets perpendicular to the joists/rafters,
the maximum distance between them is 24". The brackets
included allow for a 24" maximum span. See figure for typical
ceiling layouts. Mark the location of the ceiling brackets on the
joists/rafters or drywall, making sure the vertical supports can
be positioned between the lag bolts use to attach the brackets.
Position the center of the brackets on a 24"/48" grid as required.
8
Assembling the Rack
P2
48"
P2
P2
4' x 4'
P2
24"
P2
48"
P2
P2
2' x 8'
48"
P2
26"
P2
P2
P2
24"
48"
P2
26"
P2
2' x 8'
2.
Attach the ceiling brackets
48"
P2
F2
P2
F2
Using the provided drill bit (3/16"), drill all pilot holes in the center
of the joists/rafters. Two lag bolts must be used on each bracket,
48"
one on each side of the vertical support. Mount the ceiling
brackets (P2) using 5/16" x 3" lag bolts (F2) (8 or 12).
P2
4' x 4'
P2
F2
P3
Corner Support
(4 Required)
P4
F2
P5
P6
Center Support
(If Required)
F2
5/16" x 3" Lag bolt