L - N
P1 electric pump connection cables.
Observe the required correspondence closely and provide a good ground
connection.
L - N
P2 electric pump connection cables.
Observe the required correspondence closely and provide a good ground
connection.
5.4
Electrical Connections.
54.1
Make sure that the main switch on the power distribution panel is set to OFF (O), and that panel operation
cannot be restored accidentally, before you proceed to connect the power cables to the disconnecting switch
terminals L1-L2-L3
5.4.2
Closely observe all the regulations in force regarding safety and accident prevention.
5.3.3
Make sure that all the terminals are fastened securely, pay attention in particular to the ground terminal.
5.4.4
Connect the cables in the terminal board according to the wiring diagrams shown in the attached handbook.
5.4.5
Make sure that all the connection cables are in perfect condition, with the outer sheath undamaged.
5.4.6
WARNING ! Install differential switches on the system.
5.4.7
Verifications to be made by the installation personnel :
a) Continuity of the protection conductors and of the main and auxiliary equipotential circuits;
b) Isolation resistance of the electrical system;
c) Differential protection efficiency test;
d) Applied voltage test;
e) Operating test.
6. SPARE PARTS
2EP 0,37 M
REF
Code
362302010
AMPEROMETRIC BOARD
KL1
2EP 0,55 M
REF
Code
KL1
362302010
AMPEROMETRIC BOARD
2EP 0,75 M
REF
Code
KL1
362302010
AMPEROMETRIC BOARD
2EP 1,1 M
REF
Code
KL1
362302010
AMPEROMETRIC BOARD
2EP 1,5 M
REF
Code
KL1
362302010
AMPEROMETRIC BOARD
2EP 2,2 M
REF
Code
KL1
362302010
AMPEROMETRIC BOARD
ENGLISH
Description
Description
Description
Description
Description
Description
9
Model/Vendor
EBARA
Model/Vendor
EBARA
Model/Vendor
EBARA
Model/Vendor
EBARA
Model/Vendor
EBARA
Model/Vendor
EBARA