48
THERMEX TX MOTOR
1
NOTE: Make sure to pull the electrical wire
through the hole in the top of the conden-
ser housing.
3
The motor must be placed in a suitable
place on the ceiling, and placed on a vibra-
tion-dampening layer. This MUST be done
so that the vibrations from the motor do
not spread further to the building structu-
re.
NOTE: The motor MUST be positioned up-
right, otherwise it will cause damage to
the motor.
5
If an insulated vent hose is used, the vent must be insulated so as to prevent conden-
sation.
2
Place the included strips around the con-
denser housing.
4
Install the vent on the motor. The air inlet
from the hood is installed at the back, and
the air outlet to the outside is installed on
the flange with the non-return valve.
NOTE: It is important that the non-return
valve can open freely and unhindered.