Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example
of a time with low water usage is when a household is asleep. If there is a
demand for water when the system is regenerating, untreated water will be used.
When the system begins to regenerate, the display will change to include information about the step of
the regeneration process
and the time remaining for that step to be completed. The system runs through the steps automatically
and will reset itself to
provide treated water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system sooner
than when the system calls for it, usually referred to as
manual regeneration. There may be a period of heavy water
usage because of guests or a heavy laundry day. To initiate a manual regeneration at the preset delayed
regeneration time, when the egeneration time option is set to "NORMAL" or "NORMAL + on 0", press and
release "REGEN". The words "REGEN TODAY" will fl ash on the display to indicate that the system will
regenerate at the preset delayed regeneration time. If you pressed the "REGEN" button in error, pressing
the button again will cancel the request. Note: If the regeneration time option is set to "on 0" there is no
set delayed regeneration time so "REGEN TODAY" will not activate if "REGEN" button is pressed. To
initiate a manual regeneration immediately, press and hold the "REGEN" button for three seconds. The
system will begin to regenerate immediately. The request cannot be cancelled. Note: For softeners, if
brine tank does not contain salt, fi ll with salt and wait at least two hours before regenerating.
Set Time of Day
The user can also set the time of day. Time of day should only need to be set after power outages lasting
more than 24 hours, if the battery has been depleted and a power outage occurs or when daylight saving
time begins or ends. If a power outage lasting more than 24 hours occurs, the time of day will fl ash on
and off which indicates the time of day should be reset. If a power outage lasts less then 24 hours and the
time of day fl ashes on and off, the time of day should be reset and the non rechargeable battery
replaced.
STEP 1U – Press SET CLOCK.
STEP 2U - Current Time (hour): Set the hour of the day using ▲ or ▼. Press
NEXT to go to
Step 3U.
STEP 3U - Current Time (minutes): Set the minutes of the day using ▲ or ▼.
Press NEXT to exit
Set Clock. Press REGEN to return to previous step.
RETURN TO THE RULES 'OF SERVICE
REGEN TODAY will be
displayed if a regeneration
is expected "Tonight."