Armario de regeneración Trans therm
INSTRUCTIONS FOR JUNCTIONS
The manufacturer declines all responsibility and warranty obligation for any damage caused
by an installation which does not conform to the following instructions and norms in force.
Leave a minimum of 50 cm around the appliance in order to access the area behind it.
Supplied by a H07RNF cable supplied.
The appliance is to be connected:
to an omnipolar switch between the appliance and the electric grid, with a minimum
distance of 3 mm between the contacts for each pole.
under the control of a high sensitivity separator and with a protection against power
surges.
to an efficient earthing device conforming to norms in force.
to a potential conductor, not included with the appliance, to be connected to the 6 mm
nut, located on the lower section next to the power cable compressor.
When powering up the cabinet, check the rotation direction of the
10GN and 20GN. The rotation direction is indicated by an
the inside surface of the turbine (clockwise). If the turbines are not turning in the right
direction, cut the power supply to the cabinet, and then reverse the two phase plug.
dependent on the direction the power supply is plugged in.
The humidifier must be supplied with soft water, a stop valve being placed between the
block and the water pipe.
Water pressure must be between 150 and 500 kPa.
The water must have the following characteristics:
hardness between 3° and 6°FH
a PH higher than 7.5
a chlorine level lower than 30ppm
!Install the filter seal, delivered with the unit, at the solenoid valve inlet.
Draining is to be effected using a copper pipe or flexible, heat-resistant pipe coiled around
itself (see diagram below). A funnel (or other device) must be inserted to allow the water to
flow freely (see diagram below).
-12-
POWER SUPPLY
WATER SUPPLY
DRAINING
turbines for
arrow located on
he factory and is not