1. AUTOMATED SYSTEM 560
The FAAC model 560 operator automates two-leaf folding doors
with one operator (fig. 2-4-6) or four-leaf doors (two-leaf units on
each side) with two operators (fig. 5).
2. GENERAL INFORMATION
The operator 560 consists of an hydraulic enbloc containing an
electric motor, a pump and a hydraulic jack. All these elements
are enclosed in an anodised aluminium housing of modern,
elegant design, which also acts as an oil tank.
It can be fitted on already installed doors or doors to be installed,
without any modifications to the structure.
The operator is also suitable for outdoor installation, providing an
ordinary plastic or steel sheet housing is provided to protect it
against direct contact with atmospheric agents.
Neither a chain nor a rack are necessary to transmit drive. Motion,
obtained via a rotating telescopic arm, is silent, smooth and fast.
The FAAC 560 automated system consists of a an hydraulic power
unit, an electronic control unit and installation accessories. Figure
1 shows the operator's overall dimensions.
3. TECHNICAL DATA
OPERATOR 560
Power supply (Vac 50-60Hz)
Electric motor
Maximum absorbed power (W)
Absorbed current (A)
Thrust capacitor (µF)
Winding thermal protection (°C)
Maximum cycles/hour
Protection class
Operating ambient temperature [°C]
Max weight of gearmotor (Kg)
Type of oil
Oil quantity (l)
560 CBAC
PUMP FLOW
RATE l/min.
1,0
ANGULAR
VELOCITY °/sec.
12,4
MAXIMUM
TORQUE Nm
320
HYDRAULIC LOCK
YES
PANEL MAX
WIDTH m
1.50
AUTOMATED SYSTEM 560
Fig. 1
230 (+6 -10%)
single-phase induction 1450 rpm
220
1
8
120
80
IP54
-20 / +55
12
FAAC HP OIL
1.2
TYPE OF OPERATOR
560 SB
560 rap. CBACR
1,0
1,5
12,4
18,6
320
230
NO
YES
2.00
0.5
The fast version (CBACR) is recommended for doors with the width
of every single leaf of not less than 0.5 m.
The hydraulic lock is a special hydraulic function which guarantees
the door to lock when closing without having to use an electric
lock (maximum leaf dimensions: 1.5 m).
However, all models are supplied with a release device to facilitate
(in the SB type) or enable (in the CBAC and CBACR types) manual
opening or closing of the door.
In the SB version, an electric lock must be installed to ensure the
closing and/or opening position is maintained.
4. ELECTRICAL CONNECTIONS
IMPORTANT: arrange for the system to be earthed according to
current legal regulations.
1. hydraulic operator FAAC model 560
2. electronic control unit
3. main switch
4. 6A fuse
5. junction box
6. indoor button-board
7. key operated push-button FAAC model T10 or T11
8. radio control receiver FAAC (3x0.5) and flashing lamp (FAAC
LAMP 2x1,5)
9. electric lock if necessary (for models SB only).
6
1
5
8
7
3
9
Fig. 2
2
6
4