Troubleshooting - RIB K800 24V Manual Del Usuario

Operador irreversible para verjas correderas
Ocultar thumbs Ver también para K800 24V:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G
B
FINAL OPERATION -
Fit the gasket
T
ROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having positioned the gate in intermediate position, check the correct ignition of DL1, DL2,
DL3, DL4, DL8 leds. The led DL9 can be ignited or extinguished.
In case of no ignition of the leds, always with gate in intermediate position, check the following and replace any faulty components.
DL1
switched off
Faulty photocells
DL2
switched off
Faulty Stop button
DL3
switched off
Faulty opening limit switch
DL4
switched off
Faulty closing limit switch
During functioning with personnel present, with DIP 1 at ON, check that during opening the green DL6 LED switches on and that during closing the red DL7 LED switches
on. If not, invert the wires of the motor.
After having carried out the various connections and having supplied voltage, all the
LEDS are switched off.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various OPEN, CLOSE, K and
RADIO buttons.
By activating the K or CLOSE button the gate does not move.
The slowing phase is not performed.
The gasket shall be fitted only at the end of the installation, before you mount the
case.
The gasket is fitted
FAULT
Close the case
Check the integrity of fuses F1 and F2. In case of interrupted fuse use only of adequate
value.
F 1,6A
PROTECTION FUSE TRANSFORMER (external to the KS 24V control board)
F2 = 10A F1 =2A
Ensure to have set DIP 3 at ON.
Button OPEN always inserted.
Replace button or switch of the selector.
Faulty photocells contact with DIP 6 OFF.
Fix or replace the relative contact.
Impulse K or CLOSE always inserted.
Check and replace any buttons or micro-switches of the selector.
Execute the learning of the times through DIP 2 procedure.
Verify regulation Low speed trimmer.
32
32
Motor ready
SOLUTION
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Aa30070K800

Tabla de contenido