Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G
B
SYSTEM CHECK
After finishing the mounting procedure, check the correct working order by doing the
following:
- Check on the infrared receiver RX VERTIGO WIRELESS that the red led is on. If it is not so,
align transmitter and receiver to turn the red led on.
- Place an object between them and check that the red LED turns OFF and that at the same
time on the control panel the corresponding LED EDGE is OFF and a while the object is
present.
- Repeat the process on the other VERTIGO WIRELESS photocells installed.
- Then perform a system check of all the photocells installed by activating the movement of
the automation and checking that when an object is present the automation stops/reverses
when closing, or stops/continues to open when opening.
CLOSING THE VERTIGO WIRELESS CONTAINERS
Lastly, place the screw cover caps (6) (12) both on the TX and on the RX of the VERTIGO
WIRELESS (Fig. 2-5), by inserting them into the 4 holes so that they are perfectly attached.
CHANGING THE BATTERIES
The duration of the batteries used for VERTIGO WIRELESS photocells is about 2 years.
- To identify which VERTIGO transmitter has empty batteries, it is enough to check the red
led present on the receiver. It should be turned off in presence of no obstacles between
transmitter and receiver.
- Replace the batteries of the transmitter checking that the polarity is correct.
The automation is now ready to begin safe operation once more.
ATTENTION: Please remember that batteries must be disposed of properly according
to current standards. In case of disposal of the photocells please remember to
remove and dispose of the batteries properly.
OPTIONAL
AA ALKALINE BATTERIES
4 X 1,5V
battery life with VERTIGO WIRELESS 2 years.
AA LITHIO BATTERIES
2 X 1,5V - (buy 2 pieces)
battery life with VERTIGO WIRELESS 3 years.
For extreme temperatures -40÷+60°C.

TROUBLESHOOTING

The green LED DLTX of the TX does not turns on as you give power supply.
The red LED DLRX of the RX does not turns on as you give power supply.
The gate does not open.
The gate does not close.
code ACG9519
code ACG9509
PROBLEM
TECHNICAL SPECIFICATIONS
VERTIGO WIRELESS RECEIVER
- POWER
- MAXIMUM ABSORPTION
- OPERATING TEMPERATURE
- COVER
- BASE
- BELLOW
- PROTECTION LEVEL
- WEIGHT
VERTIGO WIRELESS TRANSMITTER
- POWER
- POWER ABSORBED
- MODULATION TYPE
- BATTERY LIFE
- OPERATING TEMPERATURE
- COVER
- BASE
- BELLOW
- PROTECTION LEVEL
- WEIGHT
TX INFRARED SIGNAL TECHNICAL DETAILS
- RANGE
- WAVELENGTH
- DIMENSION OF THE DETECTION AREA Ø 20 mm
SELF-TEST-ENABLED RIB ELECTRONIC BOARD CHART
RIB ELECTRONIC BOARD
K2007 / K2007 CRX
S1
T2 - T2 CRX
T2 24V - T2 24V CRX
APPLICATION
VERTIGO WIRELESS 8
VERTIGO WIRELESS 10
- Check batteries onTX.
- Check that on RX terminals is present the power supply 12/24V ac/dc
- Check batteries onTX.
- Check the correct allignment between TX and RX
VERTIGO WIRELESS is not aligned or stuck (red led on RX turned OFF). Check alignment
between TX and RX up to obtain red led turned on on RX.
AUTOTEST failed.
VERTIGO WIRELESS is not aligned or stuck (red led on RX turned OFF). Check alignment
between TX and RX up to obtain red led turned on on RX.
16
12/24V ac/dc
25 mA
-20°C ÷ +60°C
in polycarbonate
in ABS
in silicon
IP55
0,135 kg
alkaline batteries 2 x AA 1,5V (>2,7Ah)
3 µA
FSK
about 3 years
-20°C ÷ +60°C
in polycarbonate
in ABS
in silicon
IP55
0,130 kg
3 m
850 nm
CONNECT A/D+ TEST
ENABLE SELF-TEST
TERMINAL TO TERMINAL
FUNCTION THROUGH
A+ TEST
A+ TEST
D+ TEST
A+ TEST
MAX GATE
MAX DISPLACEMENT
WEIGHT
150 kg
13 m/min.
300 kg
10 m/min.
500 kg
13 m/min.
1000 kg
10 m/min.
CHECK
DIP 10
DIP 12
DIP 13
DIP 12
SPEED
Tabla de contenido
loading

Este manual también es adecuado para:

Vertigo wireless 8Vertigo wireless 10

Tabla de contenido