A - CONNEXIONS
J1
J2
J1
AERIAL
Radio aerial
COM
Common contact
PHOT.1 NC
Photocells contact (NC)
J2
STOP
Contact, stop pushbutton (NC)
OPEN
Contact, open pushbutton (NA)
CLOSE
Contact, close pushbutton (NA)
K BUTT.
Contact, single pulse (NA)
PED. BUTT.
Contact, pedestrian gate pushbutton (NA)
A+A-
Accessories supply 24 Vdc
SIGNAL
Led, open gate 3W max
Buzzer - Connection warning buzzer (24 Vdc
max 200 mA)
Flasher (max 20W 24 Vdc) - code ACG7061
SIGN
Low battery led
J4
EXP. 24V
Connector for EXPANDER 24V card (code
ACG5471) for SAFETY STRIP management
and other...
J5
RADIO
Connector for radio receiver (model KS 24V)
J5
RADIO
Radio receiver module (model KS 24V CRX)
J6
DO NOT TOUCH THE BRIDGE!
IF REMOVED THE ACTUATOR WILL NOT
OPERATE
J8
BATTERY
Connector for battery charge card
CHARGER
J10
SEC.
Connector for transformer secondary coil
TRANSF.
J11
Plug connector for connection of travel end
switch
LSO
Travel end contact for stopping of opening
motion
J5
J6
J4
JP1
J8
LOW
SPEED
C.S.
COM.
Common contact
LSC
Travel end contact for stopping of closure
motion
J12
MOTOR
Motor supply
LOW
Low speed adjustment trimmer
SPEED
C.S.
Current sensor adjustment trimmer
JP1
Reset
29
29
G
B
J10
J11
J12