Vetus WLOCKLT Instrucciones De Instalación página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1
Introduction
The Vetus exhaust system components are especially suitable for use
in water-injected exhaust systems.
The maximum continuous operating temperature of the plastic
components of the exhaust systems is 70 degrees C (158 degrees F).
Fit a temperature alarm to warn of excessively hot exhaust
system temperature.
If the quantity of injected coolant water is reduced to in
order to lower back-pressure in the exhaust system, check
that there is still sufficient water injected when the engine
is ticking-over. This will prevent excess temperatures in the
exhaust system.
Excess temperature can also be the consequence of insuf-
ficient mixing of coolant water with the exhaust gasses.
In general, good mixing is obtained by a virtually vertically
installed exhaust injection bend.
Poor mixing can also occur with an engine on tick-
over; especially when the coolant water injection bend is
installed virtually horizontally.
If necessary, take action. For example; by fitting a water
vortex or a water splitter in the exhaust pipe, to improve
the mixing of coolant water with the exhaust gasses.
With water-injected exhaust systems, fit a hose of suitable quality.
This hose must be reinforced, resistant to exhaust gasses, high
temperatures (100 degrees C, 212 degrees F) and oil. Easy flexibility
is essential for installation, while the hose must not collapse when
heated.
Vetus exhaust hose fulfils all the above requirements.
The complete VETUS range includes the following hose diameters:
30 mm (1.2"), 40 mm (1.6"), 50 mm (2"), 60 mm (2.4"), 65 mm (2.6"),
75 mm (3"), 90 mm (3.5"), 100 mm (4"), 110 mm (4.3"), 125 mm (4.9")
and 150 mm (5.9"). A minimum hose diameter must be used in rela-
tion to the engine power:
Engine power
Hose
to:
dia.:
10 kW (14 hp)
30 mm
18 kW (25 hp)
40 mm
23 kW (32 hp)
45 mm
29 kW (40 hp)
50 mm
40 kW (55 hp)
60 mm
50 kW (68 hp)
65 mm
4
030414.02
Engine power
Hose
to:
dia.:
65 kW (90 hp)
75 mm
95 kW (130 hp)
90 mm
118 kW (160 hp)
100 mm
142 kW (193 hp)
110 mm
184 kW (250 hp)
125 mm
265 kW (360 hp)
150 mm
If water enters the engine from the exhaust silencer into the
exhaust system (for example: under sail when the ship rolls
or pitches heavily) this will lead to irreparable damage to the
engine.
Too much water in the silencer can effect engine starting;
drain off this water first. Too much water in the silencer can be
also caused by repeated starting attempts while the engine
refuses to start.
2
Installation
Installing goose neck LT
Fit the goose neck in such a way that its top is at least 45 cm (18")
above the waterline, see drawing 1. In a sailing ship, the goose neck
should be installed as close to midships as possible.
All goose necks have a horizontal outlet as standard. It is also pos-
sible to make a vertical outlet on types LT 40/45/50/60. Section A
should then be sawn off, see drawing 2. Carefully de-burr the edges.
If possible, the goose neck should be fitted immediately above the
exhaust silencer, see drawings 3 and 5. This will reduce the amount
of water running back between the highest point and the silencer.
When the goose neck is fitted directly on the transom connection,
then the exhaust pipe maximum length between the silencer and
the highest point must be taken into account, see drawings 4 and 6.
N.B: There is no goose neck available for 30 mm (1.2") diameter
exhaust systems.
Exhaust Pipe
In order to ensure the proper drainage of the coolant water injected
into the exhaust pipe, the pipe must be installed with a slope down-
ward over its whole length from the water injection point to the
exhaust silencer.
During operation, the exhaust pipe will contain water. This will
increase its weight considerably, so support the exhaust pipe prop-
erly.
The exhaust pipe from silencer to transom connection must be
installed in such a way that:
- The highest point in the exhaust pipe should not be more than
150 cm (60") above the underside of the exhaust silencer.
- The length of the section between the exhaust silencer and the
highest point, should not exceed 300 cm (120").
W
arning
Goose neck LT
Tabla de contenido
loading

Este manual también es adecuado para:

Lt

Tabla de contenido