TROUBLESHOOTING

If the grill fails to light:
1.
Turn gas off at source and turn Control Knobs to OFF. Wait at least five minutes for
gas to clear, then retry.
2.
If your grill still fails to light, check gas supply and connections.
3.
Repeat lighting procedure. If your grill still fails to operate, turn the gas off at source,
turn the Control Knobs to OFF, then check the following:
Problem
If the grill
Misalignment of Burner
fails to light
Tubes over Orifices.
Obstruction in gas line
Plugged Orifice
Obstruction in Burner
Tubes
Misalignment of Igniter
on Burner
Disconnected Electric
Wires
Weak AA battery
If the grill
Blocking of gas line
still does not
light
GR2045401-MF-00 / GR2045402-MF-00
Possible Cause
Corrective Action
Reposition Burner Tubes over Orifices.
Remove fuel line from grill. Do not smoke! Open
gas supply for one second to clear any
obstruction from fuel line. Close off gas supply at
source and reconnect fuel line to grill.
Remove the screw from the rear of each Burner
using a Phillips Head Screwdriver. Remove the
Orifice from gas valve and gently clear any
obstruction with a fine wire. Then reinstall all
Orifices, Burners, fixing bolts and cooking
components.
If an obstruction is suspected in Gas Valves or
Manifold, call customer service.
Follow the Burner Tube cleaning procedure on
page 22 of this Operator's Manual.
Check for proper position of the Electrode Tip is
pointing to a burner port. The gap between the
Spark Electrode Tip and Spark Receiver should
be approximately 3/16 in. Adjust if necessary.
With the gas supply closed and all Control Knobs
set to OFF press the Electric Igniter cap and
check for the presence of a spark at the
Electrode.
Inspect the Igniter Junction Box Found behind
the Control Panel. Connect loose Electric wires to
Junction Box and try to light the grill.
Unscrew the Igniter Cap and replace the battery.
You may need to purge air from the gas line or
reset the regulator excess gas flow device.
Note: This procedure should be done every time
a new LP Gas tank is connected to your grill.