ENGLISH
Valve design
Valve connections
EN ISO 16135:2007
Threads: ISO 7-1, ISO 228-1
Flanges: EN 558-1, EN 1092-1
PVC-U, CPVC: ISO 15493
PPH, PE-100: ISO 15494
Valve operating torque
Operating torque values at rated pressure (PN) and 20 °C as supplied by default from the factory. Installation and operating conditions
(pressure and temperature) may affect these values.
The actuator required for an automatic operation must be calculated according to some safety factors that were determined in tests
carried out in the factory.
Operating torque table (N·m)
DN15
DN20
N·m
1
2
lbf·inch
8,9
17,7
4.
DIMENSIONS
Fig. 4
Actuator coupling dimensions (T4.2)
DN
ISO FLANGE
15
F03-F04-F05
20
F03-F04-F05
25
F05
32
F05
40
F05-F07
50
F05-F07
65
F07
80
F07
[IND] ELECTRIC BALL VALVE
Actuator coupling
EN/ISO 5211
(T3.2)
DN25
DN32
DN40
3,5
3,5
5
31
31
44,3
SQUARE OPTIONS (mm)
9/11/14
9/11/14
11/14
11/14
11/14/17
11/14/17
17
17 / 22
Pressure loss table (T3.3)
DN
10
15
20
25
32
40
50
65
80
DN50
DN65
DN80
DN100
15
25
45
132,8
221,3
398,3
DN
D / G
15
16 - 3/8"
15
20 - 1/2"
20
25 - 3/4"
25
32 - 1"
32
40 - 1 1/4"
40
50 - 1 1/2"
50
63 - 2"
65
75 - 2 1/2"
80
90 - 3"
100
110 - 4"
See the actuator manual to check the dimensions M and N.
Check the technical catalog for the rest of dimensions for flange con-
nections, PE-100, PPH butt welding PPH and the rest of end connectors.
Fig. 5
D
Kv (l/min)
Cv (GPM)
16
75
5,3
20
190
13,3
25
380
26,6
32
690
48,3
40
980
68,6
50
1600
112
63
3000
210,1
75
5500
385,2
90
6800
476,2
T 4.1(mm)
L
H
E
F
13
87
50
64
16
87
50
64
19
101
61
64
22
122
70
74
26
135
81
74
31
149
96
88
38
174
118
88
44
216
146
123
51
256
176
123
63
359
225
165
7