8. CONNECT WIRING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power from being switched on accidentally.
A
I
:
LL
NSTALLATIONS
Remove the hood wiring box cover. Install wire clamp(s) on back side of the hood. Position the hood below its future location.
NOTE: The hole for the power cable is already done. Punch the other knock-out only if installing exterior blower or in-line blower.
8.1 I
B
:
NTERIOR
LOWER
Pass the power cable through the wire clamp in the wiring box and tighten the clamp to secure the cable. Discard the wire connector
joining BLACK and WHITE wires from wiring box receptacle. Connect power cable into wiring box using provided waterproof
wire connectors.
Connect wires as follow: BLACK wire from power cable to BLACK wire from hood control
panel (A), all WHITE wires together (B), BLACK wire from wiring box receptacle to ORANGE
wire from hood control panel (C), and GREEN or BARE wire under ground screw (D).
DO NOT FORGET TO CONNECT THE GROUND. Reinstall the wiring box cover.
W
ATERPROOF WIRE CONNECTORS INSTRUCTIONS
1. Strip wires 3/8''.
2. Align frayed strands or conductors.
3. Do not pre-twist. Place stripped wires together with ends even, but lead smaller
stranded wires slightly ahead of larger solid or stranded wire.
4. Twist connector onto wires pushing firmly until hand-tight. DO NOT over torque.
5. When inserting wires into connectors, some sealant may leak out. Wipe off excess
sealant in and around conductors. DO NOT REUSE.
8.2 E
I
-L
XTERIOR OR
N
INE
Pass the power cable and the exterior or in-line blower cable through the wire clamps in the wiring box and tighten the clamps
to secure the cables. DO NOT REMOVE the wire connector joining BLACK and WHITE wires from wiring box receptacle (A).
Using provided waterproof wire connectors, connect wires as follow: BLACK wire from
power cable to BLACK wire from hood control panel (B), all WHITE wires together (C),
BLACK wire from exterior or in-line blower to ORANGE wire from hood control panel (D),
and GREEN or BARE wires under ground screws (E). DO NOT FORGET TO CONNECT
THE GROUND. Reinstall the wiring box cover.
W
ATERPROOF WIRE CONNECTORS INSTRUCTIONS
1. Strip wires 3/8''.
2. Align frayed strands or conductors.
3. Do not pre-twist. Place stripped wires together with ends even, but lead smaller
stranded wires slightly ahead of larger solid or stranded wire.
4. Twist connector onto wires pushing firmly until hand-tight. DO NOT over torque.
5. When inserting wires into connectors, some sealant may leak out. Wipe off excess
sealant in and around conductors. DO NOT REUSE.
:
B
:
LOWER
:
!
WARNING
- 7 -
P
OWER CABLE
A
B
D
HE0081
E
-
P
XTERIOR OR IN
LINE
OWER CABLE
BLOWER
B
CABLE
D
C
E
HE0080
C
A