User-Maintenance Instructions; Clearing A Jam From The Tool; Technical Service; Fastener And Replacement Parts - Campbell Hausfeld CHN20102 Manual De Instrucciones De Operación

Clavadora para acabado
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operating Instructions
User - Maintenance
Instructions

CLEARING A JAM FROM THE TOOL

1. Disconnect the air
supply from the
tool.
2. Remove all nails
from the magazine
(see Loading/
Unloading). Failure
to do so will cause
the nails to eject from the front of
the tool.
3. Undo latch by
pulling out
and down. The
wire latch will
disengage from
the hooks on the nose.
4. The door can
now be rotated,
exposing the
jammed fastener.
5. Remove the
jammed fastener,
using pliers or
a screwdriver if
required.
6. Rotate door back
into the closed
position.
7. Extend the wire
latch and place
over the hooks on
the nose.
8. Close the latch by
pushing the latch
up and in until the
latch snaps into
place.
9. Make sure the
trigger and work
contact element
(WCE) move freely
up and down
without sticking or binding.
www.chpower.com

TECHNICAL SERVICE

Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual.
FASTENER AND REPLACEMENT
PARTS
Use only headless
micropins, 16 gauge.
Tool performance, safety and durability
could be reduced if improper fasteners
are used. When ordering replacement
parts or fasteners, specify by part
number.

TOOL REPAIR

Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
Fasteners
The following Campbell Hausfeld finishing nails are available at local retail stores.
If you need help locating any item, call customer service at 1-800-543-6400.
Campbell Hausfeld nails meet or exceed ASTM Standard F1667.
Shank
Model
Length
Gauge
FB005060
2
inch
Gauge
FB160025
1
inch
Gauge
FB160040
1-1/2
inch
Gauge
FB160065
2-1/2
inch
Gauge
Interchange Information
Nails used in the Campbell Hausfeld CHN201 Finishing Nailer will also work in
Hitachi NT65A, Paslode 3250-F16, IM250F, Duo Fast LFN-764, Sears 18321, Porter
Cable FN200 and FN250.
6

ASSEMBLY PROCEDURE FOR SEALS

When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots. After
reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing.
STORAGE
The tool should be stored in a cool dry
place.
Finish
Head
16
Galvanized
Brad
16
Galvanized
Brad
16
Galvanized
Brad
16
Galvanized
Brad
CHN20102
Nails
Nails
Per
Per
Collation
Stick
Box
Adhesive
50
2500
Adhesive
50
1000
Adhesive
50
1000
Adhesive
50
1000
Tabla de contenido
loading

Tabla de contenido