Failure of electric elements due to lime scale build-up on the heating surface, low pH, or other imbalance IS NOT
covered by the warranty.
C. Technical Specifications and Dimensions
Model
*Wattage (kW)
18kW
18
24kW
24
27kW
27
36kW
36
Technical Data
Minimum Water Flow to Activate
Unit
Working Pressure
Tested Pressure
Water Connections
Elements
Dimensions
Weight (Empty)
Temperature Range
Temperature Rise Δt (
35
45
77
Table 3 - Technical Specifications - *Wattage based on maximum voltage.

Part 3 - Installation Instructions

A. Wall Mounting the Water Heater
1. Remove the two (2) screws attaching the water heater front cover. Remove the front cover. (Figure 1.)
Do not install the unit above electrical boxes or junctions.
The mounting surface must be solid and secure.
2. Position the unit on the mounting surface. Ensure the unit is level. Mount the unit to the wall with four (4)
screws of at least one (1) inch (25.4mm) in length at the marked points. See Figure 2.
Use screws suitable for the wall material and the weight of the water heater. Failure to do so could result in
property damages and damage to the water heater. Such damages ARE NOT covered by product warranty.
The appliance must be mounted horizontally, with water inlets and outlets at the bottom. See Figure 3.
This water heater must be installed upright in the vertical position as described in this manual. DO NOT attempt
to install this water heater in any other orientation. Doing so will result in improper water heater operation and
property damage, and could result in serious personal injury or death.
Pull gently on the water heater to ensure that it is properly mounted.
Max Amperage
75
100
112.5
150
18 - 27kW
36kW
18 - 27kW
20.7" (526 mm) Width x 13.3" (339 mm) Height x 4.5" (114 mm) Depth
36kW
25" (636 mm) Width x 13.3" (339 mm) Height x 4.5" (114 mm) Depth
18 - 27kW
36kW
o
F)
18kw
3.51
2.73
1.59
Required Breaker(s)
3 x 30A Double Pole
3 x 40A Double Pole
4 x 40A Double Pole
All Models
0.5 gpm
7 - 150 psi (0.5 - 10 bar)
290 psi (20 bar)
3/4" NPT
2
3
12.17 lb (5.52 kg)
16.23 lb (7.36 kg)
o
86 - 122
F (30 - 50
Flow Rate (GPM)
24kw
4.68
3.64
2.12
7
Required Wire Size
3 x 10 AWG w/ Ground
3 x 8 AWG w/ Ground
4 x 8 AWG w/ Ground
o
C)
27kW
36kW
5.26
7.02
4.09
5.46
2.39
3.19
EN