PROBE TECHNICAL DATA
Operation voltage
5Vdc
Resistance
10K ±2% (at 25°C)
Working temperature
-30 ÷ +55°C
TECHNICAL SPECIFICATIONS
- Temperature range
- Humidity
- Power supply voltage
- Frequency
- Maximum absorption
- Power supply microinterruptions
- Maximum power SIGNAL output
- Maximum load of blinker output
- Current available for photocells and accessories
- Current available on radio connector
TECHNICAL RADIO SPECIFICATIONS (model B2-CRX)
- Reception frequency
433,92 MHz
- Impedence
52 ohm
- Sensitivity
>1 µV
- Feedback control
PLL
- Memory storage (codes)
1000
- All the inputs must be used as clean contacts because the power supply is generated
internally (safe voltage) in the card and it is set in a way to guarantee the use of the double
insulation and reinforced in relation to parts with hazardous voltage.
- Any external circuits connected to the outputs of the control board, must be carried out to
make sure the double or reinforced insulation is used in relation to parts with hazardous
voltage.
- All the inputs are run by a programmed integrated circuit which carries out a self-check at
the beginning of each operation.
TROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having positioned
the gate in intermediate position, check the correct ignition of red LEDS DL6, DL7, DL8, DL9
and DL10.
In case of no ignition of the LEDS, always with gate in intermediate position, check the
following and replace any faulty components.
DL6
OFF
Stop button malfunction (if Stop is not connected, perform
the jump between COM A+ and STOP).
DL7 or DL8
OFF
Faulty photocells (In case the edge is not connected, carry
out jumper between COM A+ and PHOTO 1/PHOTO 2)
DL9 or DL10
OFF
Faulty safety edge (In case the edge is not connected, carry
out jumper between COM A+ and EDGE 1/EDGE 2)
During functioning with personnel present, with DIP 1 at ON, check that during opening of M1
and M2 the green DL2 and DL4 LEDS switch on and that during closing of M1 and M2 the
red DL3 and DL5 LEDS switch on.
Or else, reverse the wires of the motor.
LED DL13 (BLUE)
ON
Some functions are enabled via smartphone, so via
smartphone check the card functions as the dips/trimmers status may not be true.
On the board there are resettable fuses which intervene in the event of a short circuit,
interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the cause
of the fault.
-10 ÷ + 55°C
< 95% without condensation
230 o 120V~ ±10%
50/60 Hz
45 mA
100ms
24 Vdc 3W
40W with resistive charge
500mA 24 Vdc
200mA 24 Vdc
29
G
B