Warning signs:

Avoid accidents by always following the safety
instructions given in the user manual and on the safety
signs placed on the blower.
Warning signs with symbols without text may be found
on the blower. The symbols are explained below.
Read the user manual carefully and
observe the warning texts in the user
manual and on the blower.
Rotating parts must only be touched
when they are at a complete stand-
still.
Always disconnect electricity prior
to repairs and maintenance, and
make sure that the blower cannot be
started by mistake.
Mounting:
Be careful when moving the blower. Always use strap
or similar fixed to the lifting point on the base frame,
when lifting the big blowers TRL 300 and TRL 500.
Alternatively, use a fork-lifter grabbing under the base
frame of the blower.
Mount the blower on a solid and plane base. Allow
during installation for easy access for repair and
maintenance. See that the access for cooling air to the
room housing the blower is sufficient.
See that there is sufficient access for fresh air to the
room, from which the blower takes the suction air.
The blower is designed for indoor use. In cases where
the blower is placed outside, always protect is from fall
by using a cover.
Mounting pipe system for blower
Always secure pipes mounted directly on the blower
outlet by using clamps with bolts, in a way that the
pipes cannot be removed without tools. Always use the
special safety clamp delivered with the blower. Never
use quick release clamps on the blower outlet.
The pipe attached to the blower outlet must have
a length of minimum 850mm, with a diameter of
maximum 200 mm, in order to prevent the possibility
for coming in contact with the blower/rotary valve rotor
when the pipe is mounted.

Electrical installation:

Check that the local mains supply meets the electrical
equipment specification of the blower.
All electrical installations must be effected according to
the current legislation.
In cases where the blower is delivered with blower
control box from the factory, a control diagram is
placed inside the blower control box.