Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

6. Indication LEDs:
o
LED LINE green: Power supply, lights up when connected.
o
LED FAILURE red: flashing for temporary error, fixed light for permanent definitive error .
o
LED PUMP yellow: On indicates that the pump is in operation. Off indicates that the pump is not in
operation.
o
flashing blinking this indicates that it is the auxiliary.
7.
The button
ON/OFF: It allows switching from AUTOMATIC to MANUAL and vice versa.
COMMISSIONING - PLUG AND PLAY
Proceed with pump priming (follow the instructions in the pump manual).
Connect the device to the mains with the switch, all the circuit breaker lights will be come on instantly. The unit will carry
out a SELF-TEST for 10 seconds, after which the
display will show the device model and will immediately show the Configuration menu.
The appliance is ready to be configured.
IN MASTER & SLAVE MODE.
To install two devices to work in group format, proceed in a manner similar to the above instructions. The order in which the
devices are connected is irrelevant. During the configuration stage set one device as "slave" and the other as "master".

CONFIGURATION

Change the values by using the buttons
various screens are automatically displayed one after another which represent the Configuration sequence. Press the button
MENU to exit the configuration sequence at any time while saving that values modified to that point.
Display
P L I N E
P S E T
2
,
2 b a r
3
,
5 b a r
M E N U
L A N G U A G E
E N G L I S H
I M A X P U M P
O F F
R O T A T I O N S E N S E
0
0 H z
M I N . S P E E D
1 5
H z
LED AUT green: pump on in automatic mode.
"FAILURE" LED goes off and the
and
ENTER to store the data. After each press of the button
To start the configuration sequence press the
This is the access screen of the Configuration menu.
Use the buttons
to choose from the following languages: "LANGUAGE ENGLISH", "LANGUE
FRANÇAIS", "LINGUA ITALIANA" e "SPRACHE DEUTSCH "IDIOMA ESPAÑOL".
Use the buttons
to enter the value of the rated current in A of the pump to enable thermal
protection. This value is indicated on the technical characteristics data plate of the pump motor. Press the button
ENTER to validate.
With the button
START/STOP check the direction of rotation of the pump. With the buttons
(0/1) reverse the direction of rotation. Press the button
Use the buttons
to set the lower limit of the rotation speed of the pump motor.
In MASTER & SLAVE mode. If the light is
"LINE" indicator comes on. The
Description
MENU button for 3 seconds when the pump is stopped.
ENTER to validate.
EN
ENTER the
button
MENU for 3s
ENTER
ENTER
ENTER
ENTER
Enter
17

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Nocchi vsd 6 m/tNocchi vsd 10 m/tNocchi vsd 9 t/tNocchi vsd 14 t/t

Tabla de contenido