Indoor unit outline
120mm or
more to wall
Left rear side
refrigerant pipe
hole Ø 65
Drill piping hole
1. Slant the piping hole (Ø 65 mm) on
the wall slightly downward to the
outdoor side.
2. Insert the piping-hole sleeve into the
hole to prevent damage to the
connection piping and wiring.
Indoor
Installing the drain hose
1. Connect the drain hose to the outlet
pipe of the indoor unit. Bind the joint
with rubber belt.
2. Put the drain hose into the insulating
tube.
3. Wrap the insulating tube with wide
rubber belt to prevent the insulating
tube from shifting. Slant the drain
hose slightly downward for smooth
drainage of the condensate water.
NOTE
The insulating tube must be
connected reliably with the sleeve
outside the outlet pipe. The drain
must be slanted downward slightly
150mm or more to ceiling
Wall
Outdoor
24000Btu/h models
without distortion, bulge or fluctuation.
Do not put the outlet of the drain hose
in water to prevent the drain hose
from freezing.
Wiring connection of indoor unit
Terminal block of indoor unit
CAUTION
Check the wiring to make sure that
there is no short circuit. Incorrect
wiring can cause malfunction.
Ensure the colour of wires of outdoor
unit and the terminal Nos. are the
same to the indoor's respectively.
The indoor power cord (purchared on
local) type is H05VV-F or H05V2V2-F,
the outdoor power cord and
interconnected cord type is H07RN-F.
Installation plate
120mm or
more to wall
Right rear side
refrigerant pipe
hole Ø 65
Front Panel
Electronic
box cover
W
1(L)
2(N)
S
To outdoor unit