9
Your vacuum cleaner comes with a power regulator
helping you to smoothly regulate its power. Power can
regulated with the slider.
10
Sliding the slider according to the marking (MAX
or MIN) will cause the suction power to increase or
decrease.
11
Your vacuum cleaner is also fitted with mechanical
suction regulator located on the hose handle. It allows
you to temporarily and slightly correct the suction
power without the need to use the slider.
Filter disassembly
Before you replace the filters, make sure that the vacuum
has been switched off and the plug is removed from
the power outlet.
EPA BASIC FILTER AND FOAM FILTER
It is necessary to clean EPA basic filter from the fine dust
fractions from time to time.
1
Switch the vacuum off by pressing ON/OFF
button (7).
2
Remove the plug from the power outlet.
3
Press the two side buttons located on the hose end
and remove the ending of the hose from the inlet opening.
4
Raise the front cover interlock (8) and open the lid (6).
5
Remove "CYCLONE" dust container (15) from the
vacuum.
6
Press EPA basic filter' s interlock (13) and remove
EPA basic filter from "CYCLONE" dust container.
7
Remove foam filter (14). If the foam filter (14) gets
dirty, you can rinse under running water. Remember to
dry the filter before you reattach it.
The main function of the foam filter (14) is to protect EPA
basic filter (13) against excessive dirt.
For safety reasons, attaching damp or
damaged foam filter is not acceptable.
8
Clean EPA basic filter (13), if your filter is damaged,
you must replace it with a new one. If EPA basic filter
(13) gets dirty, you can also rinse it (13) under running
water. Remember to dry the filter before you reattach it.
For safety reasons, attaching damp or
damaged EPA basic filter (13) is not
acceptable.
9
Reinsert the foam filter.
10
Reinsert the new/rinsed EPA filter (13), make sure
that the two splines in the bottom part of the EPA filter
(13) fit into the slots in the dust container.
11
Insert "CYCLONE" dust container fitted with EPA
basic filter (13) into the vacuum' s compartment.
12
Close the front cover of the vacuum.
OUTLET FILTER
1
In order to replace outlet filter (12) press the outlet
filter cover interlock and remove the outlet filter cover
from the vacuum cleaner.
2
Remove the outlet filter from the filter cover.
If the outlet filter (12) gets dirty, you can also rinse it (12)
under running water. Remember to dry the filter before
you reattach it.
C
For safety reasons, attaching damp or
damaged outlet filter is not acceptable.
3
Carefully attach the new/rinsed filter in the filter cover.
4
Place the filter cover back making sure that the two
splines located in the bottom part of the cover fit into
the slots on the vacuum' s hosing, press the cover in
order for the clip to lock in the hosing. The click you hear
confirms that the outlet filter cover has been correctly
attached.
Damaged outlet filter should always be
replaced with a factory new and original
item.
Dismantling/attaching "CYCLONE"
dust container
Your vacuum cleaner comes with a removable "CYCLONE"
dust container (vacuum' s removable module) that
collects and holds the dirt. When "CYCLONE" is full,
you need to empty it.
Your vacuum cleaner is equipped with
safety valve located inside the vacuum's
compartment. It opens automatically,
when the suction hose or any of the elements
attached to it get choked or "CYCLONE" dust
container is overfull. Once the valve opens, you
will hear a distinctive "whirring" sound coming
out of the machine.
D