Manual Override - GAPOSA SIDONE LP25012T Manual De Instrucciones

Motorreductor con anticaídas integrado para puertas de garajes, puertas industriales y comerciales
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7. MANUAL OVERRIDE

If a black-out occurs and you need to manually operate the shutter you must first check which manual device is your
SIDONE equipped with:
- manual overraid with chain
- standard handle
and according to the device you have, proceed as follows.
WARNING: Before manually operate the shutter, disconnect the main power supply. This prescription must be followed
even if the manual operation is equipped with an electrical safety. Remember to re-connect the power supply after the
emergency operation.
WARNING: The door, when moved manually through one of the 2 above mentioned devices, must never overcome the up
or down limit switches otherwise the door risks to be damaged and the limit overcoming activates the safety switches
with the result that electrical operation will then be possible only after the intervention of a technician disabling the
protection.
7.1 MANUAL OVERRIDE WITH CHAIN
To manually activate the shutter with the manual override
with chain you must:
1. Pull the red knob and simultaneously the chain until the
override engages the motor shaft and stops, through the
safety micro, the power supply.
2. Manually lift or lower the shutter by means of the chain.
WARNING: handle the chain uniformly without tugging.
3. When the manual override is accomplished, pull the gre-
en knob to turn the power supply on.
WARNING: Check that the safety override is unlocked other-
wise the motor cannot be activated electrically.
7.2 STANDARD HANDLE
To manually operate the shutter by means of the handle proceed as follows:
1. insert the handle into the back of the motor and turn it until it engages the motor
shaft;
While introducing it, a safety micro will turn the power supply off.
2. Turn the handle clockwise to open the shutter or anticlockwise to close it.
3. Once the manual operation is accomplished remove the handle.
Pulling the crank the supply voltage is reactivated.
90°
installation
possible
11
Tabla de contenido
loading

Este manual también es adecuado para:

Sidone lp40011tSidone lp55011tSidone lp65011t

Tabla de contenido