4. Troubleshooting
Problem
Charger does not
function
The battery is not fully
charged
The battery is being
overcharged
12
Possible cause
Reversed PV connection
Reverse battery
connection
A bad battery connection
Cable losses too high
Large ambient
temperature difference
between charger and
battery (T
ambient_chrg
T
)
ambient_batt
Only for a 24V system:
wrong system voltage
chosen (12V instead of
24V) by the charge
controller
A battery cell is defect
Large ambient
temperature difference
between charger and
battery (T
ambient_chrg
T
)
ambient_batt
Solution
Connect PV correctly
Non replacable fuse
blown.
Return to VE for repair
Check battery
connection
Use cables with larger
cross section
Make sure that
ambient conditions
are equal for charger
>
and battery
Disconnect PV and
battery, after making
sure that the battery
voltage is at least
>19V, reconnect
properly
(reconnect battery
first)
Replace battery
Make sure that
ambient conditions
are equal for charger
<
and battery