11. Cut support wire (B) into 4 pieces of equal length.
NOTE:
Ceiling structure more than 3ft (0.91m) above tray (A)
will require additional #12 annealed steel wire.
SUPPORT WIRE INSTALLATION
WARNING:
Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer's responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
Solid Concrete Ceiling Structure
WARNING:
Anchors must be installed into structurally
sound solid concrete with a minimum thickness of 1.75"
(44.5mm) or greater. Installation into concrete that exhibits
cracking, spalling, or other defects may result in failure of
anchor and serious personal injury or damage to equipment!
1.
Drill 1/4" (6.4mm) diameter x 1-3/8" (35mm) deep hole at
each marked wire anchor support location. (See Figure 7)
Ensure hole is at least 2-1/2" (64mm) from nearest concrete
edge. Remove debris from hole.
1
2
1/4"
(6.4mm)
(H) x 4
Figure 7
2.
Tap anchor (H) into each hole to a depth of at least 1"
(25mm). (See Figure 7)
WARNING:
Failure to properly set anchor may result in
failure of anchor and serious personal injury or damage to
equipment!
3.
Using claw portion of hammer, set each anchor (H) by
pulling it out of hole approximately 1/4" (6.4mm). (See
Figure 7)
4.
Insert support wire (B) through hole in anchor. Twist wire
tightly around itself at least four complete turns, and then
thread loose end between anchor and first turn. (See
Figure 7) Repeat for three remaining support locations.
8
3
4
(B)
Steel Truss Ceiling Structure
1.
Route end of support wire (B) over truss at marked wire
anchor support location. Twist wire tightly around itself at
least four complete turns, and then thread loose end
between truss and first turn. (See Figure 8) Repeat for three
remaining support locations.
1
Figure 8
Wood Ceiling Structure
WARNING:
Anchors must be installed into wood with a
minimum thickness of 1-1/2" (3.81 cm) and a minimum depth
of 3-1/2" (8.89 cm) or greater.
1.
Drill 5/32" (4.0mm) diameter x 2" (51mm) deep hole at each
marked wire anchor support location. (See Figure 9)
Remove debris from hole.
1
5/32"
(4.0mm)
Figure 9
2.
Fully thread eye lag (J) into each hole. (See Figure 9)
3.
Insert support wire (B) through eye lag (J). Twist wire tightly
around itself at least four complete turns, and then thread
loose end between eye and first turn. (See Figure 9) Repeat
for three remaining support locations.
Installation Instructions
(B)
(J)
2
3
(B)