ELPMBP05
SITE PREPARATION / ASSEMBLY
NOTE:
The ELPMBP05 may either be installed on top of, or in
place of, an existing ceiling tile.
NOTE:
The ELPMBP05 can accommodate one 1-1/2" NPT or
NPSM following ANSI/ASME B1.20.1 (Schedule 40,
0.154" minimum thickness steel or aluminum - ASTM
B221) threaded extension column (not included)
located in center of assembly (See Figure 1). Threaded
extension column must have a minimum of four threads
engaged.
Figure 1
1.
Select the best mounting location based upon the following
items (See Figure 2):
•
Dimensional offset of display/projector relative to
column (due to mount and/or interface).
•
For Projectors: Any recommended dimensions of
projector relative to target (see installation instructions
included with the projector).
Figure 2
2.
Remove adjacent ceiling tiles for access. Do NOT remove
tile affected by installation of extension column.
6
3.
4.
NOTE:
5.
1
Lay assembly (A) on top of ceiling tile so that extension
column support is aligned with location noted in Step 1.
Mark locations for hanger brackets (D) on tray (A) with
pencil (See Figure 3). Each hanger bracket (D) may be
installed in one of 3 locations in each corner of tray (A),
dependent upon specific installation requirements. Ensure
brackets (D) are located as follows:
•
On sides of tray (A) adjacent to primary (1-1/2" (38mm)
high) rails of ceiling framework.
•
As close to corner of tray (A) as installation allows.
Proceed to the appropriate installation situation.
Installation on Top of Existing Tile only: Mark the
following locations on ceiling tile with pencil (See Figure 3):
A.
Extension column hole
B.
OPTIONAL: Electrical cutout
4
(D) x 4
(A)
8B
5B
Figure 3
Installation Instructions
1.5" (38mm)
8A
5A