Milestone ELPMBP05 Instrucciones De Instalación página 7

Kit de reemplazo de panel de cielo raso suspendido
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation Instructions
6.
Examine ceiling structure (concrete, steel truss, or wood)
above tray (A) to identify the following (See Figure 4):
Four support wire anchor locations, each
approximately 15° outboard of corresponding hanger
bracket (D). Mark locations with pencil.
One safety cable anchor location directly above center
of tray (A). Mark location with pencil.
NOTE:
Hanger brackets (D) and turnbuckles (F) are installed
later; they are shown for reference only. (See Figure 4)
15°
x4
6
(D) x 4
15°
x4
Figure 4
7.
Remove tray (A) and affected ceiling tile.
8.
Installation on Top of Existing Tile only: Cut the following
holes in ceiling tile (See Figure 3):
A.
Cut extension column hole in tile at marked location,
2" (51mm) minimum diameter.
B.
OPTIONAL: Cut electrical box opening in tile at
marked location. Install UL Listed electrical box (not
included) to tray (A) following instructions included
with electrical box.
9.
Install four hanger brackets (D) to tray (A) with eight
1/4-20 x 3/8" Phillips head screws (K) at marked locations
(See Figure 5). Ensure brackets (D) are installed against
inside flanges of tray (A).
NOTE:
Some installations may require that one or more
brackets (D) be installed after tray (A) is positioned in
suspended ceiling framework.
x 5
(A)
9
(K) x 8
10. Loosely install ceiling framework clamps (E) to hanger
brackets (D) using 1/4-20 x 1" Phillips head screws (L). (See
Figure 6)
FOR INSTALLATION ON TOP OF EXISTING TILE:
Use lower hole on bracket (D).
FOR REPLACEMENT OF EXISTING TILE:
Use middle hole on bracket (D).
NOTE:
Top hole reserved for installation of turnbuckle (F).
(E) x 4
ELPMBP05
(A)
Figure 5
(D) x 4
(L) x 4
10
(A)
Figure 6
(D) x 4
7
Tabla de contenido