Nussbaum SMART LIFT 2.30 SL Instrucciones De Servicio página 124

Ocultar thumbs Ver también para SMART LIFT 2.30 SL:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

8.7.4 Selection the Liebig anchor with floor cover (screed, tiles)
Hole diameter 26 mm in the baseplate
Liebig anchor
Anchor type
Drill depth (mm)
Min. anchoring depth (mm)
Concrete thickness (mm)
Drill diameter (mm)
Component thickness (mm) e + f
Concrete quality
Number of anchors (pc.)
Torque of the anchors
(*) Min. concrete thickness when using the above-mentioned anchor, otherwise follow the details in the
foundation plans.
Similar value anchors and other known brands of anchor manufacturers can be used when considering
the conditions.
(1) Description of normal reinforcement:
A normal reinforcement is present if the axis separation in the area of the anchor with a rod diameter of
≥ 10 mm is 150 mm, or for a rod diameter of ≤ 10 mm is 100 mm.
124
BM16-25/100/65
a
125
b
100
c
min. 200*
d
25
40 – 65
Min.C20/25 normal reinforcement
depending on the lift type
115 Nm
OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL - HYMAX S 3000-S3500-S4000_V1.2_DE-EN-FR-ES-IT
BM16-25/100/100
125
100
min. 200*
25
65 – 100
1
115 Nm
Tabla de contenido
loading

Tabla de contenido