Technical Information; Drilling Dimensions - Webasto SmarTemp Control 2.0 Instrucciones De Operación Y Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SmarTemp Control
Status Indicator Lights - The Red status indicators (heater "ON") and LCD screen backlight turn off
after 30 seconds. A touch of any button or a turn of the rotary knob will re-activate these lights. If the
"Webasto" button is used to re-activate these lights, an additional press of this button is necessary to
turn the heater off. Note that when the heater is "ON" the display is active.

Technical Information:

– Rated Voltage: 12V / 24V
– Operating Voltage Range: 9V - 32V
– Low Voltage Disconnect Range: 12V: 11 – 12.5V | 24V: 21 – 25.5V
– Operating Temperature: - 40° ... +185 °F (- 40° ... +85 °C)
Note: Display visible to -22°F (-30°C)
– Set Temperature Range: 41° - 95° F (5° - 35° C)
– Installation Dimensions: (L x H x D) 2.7" x 2.2" x .60" (69.4mm x 55.5mm x 15.2mm)

Drilling Dimensions

Use the dimensions / template located in the back of this manual as a guide when installing and
mounting the Webasto SmarTemp Control 2.0.
NOTE: The Webasto SmarTemp Control 2.0 has an integrated ambient temperature sensor. To
ensure this sensor properly measures the surrounding air, the unit must only be mounted in the
vertical position.