SmarTemp Control
Mode
Language
Temp Unit
Options
 Duration
 LVD
 Password
 PM Reminder
Definitions
Mode changes the operation of the heater between heat mode and
ventilation mode. Status indicator lights will illuminate red for heat
mode and blue for ventilation mode when the selected mode is
active.
Note: Refer to Status Indicator Light description on page 6 for
additional Status Indicator explanation.
Language changes between English, Spanish, and French.
Temp Unit changes between Fahrenheit and Celsius units of
measure.
Advanced level adjustments; see below.
Duration allows for the selection of continuous heater operation or
timed operation (30 minutes – 14 hours in 30 minute increments).
IMPORTANT: Timed duration is not to be mistaken for Timer
functionality. The duration times above are used when turning the
heater on manually. I.e. set the heater duration for 8 hours before
heading to bed.
Note: If timed operation is selected 10 hours is default.
LVD "Low Voltage Disconnect" allows the user to set the battery
voltage level at which the Webasto SmarTemp Control 2.0 will shut
down the heater. A warning (LED and message) will appear after 8
minutes of low voltage. The warning will remain on for 2 minutes
before the heater is shut off.
If battery voltage is equal to or less than the threshold selected
+0.1v, the heater will not start. I.e. if an 11.5v threshold is selected
the heater cannot be started until B+ has reached 11.7v.
12 volt - Range between 11v – 12.5v
24 volt - Range between 21v – 25.5v
A password can be set to prevent access to the advanced "Options"
menu. Enter a 4 digit code passcode to begin securing the
"Options" menu.
Note: This is typically used in fleet vehicle applications.
If the heater has not run 30 days, the preventive maintenance (PM)
reminder will alert the operator with a message to run the heater for
20 minutes. The indicator lights will flash red as a visual reminder.
The operator will have the ability to Start the 20 minute
maintenance cycle or delay it via a "Snooze" option. When Snooze
is selected the PM reminder will postpone until 12:00PM the
following day.
Installation - Operating Instructions
6
Default
Heat Mode
English
Fahrenheit
Continuous
11.4v
24.2v
OFF
ON