5.
OPERATION
This water heater is designed for DHW supply in residential or industrial applications.
It can be installed in any CH or solar panel heating system.
The water heater must be connected to the water supply via the cold water coupling and to DHW utilities via the hot water
coupling. When DHW is required, cold water enters the water heater where it is heated to the temperature set on the
thermostat, if there is one.
The ideal setting is 60-65°C because this temperature guarantees the best performance of the water heater as well as:
- maximum hygiene
- cost effectiveness
- reduced scaling
DHW in the tank is heated by CH/solar heated water fl owing through the heat exchangers.
6.
SAMPLE LAYOUTS
The examples given below are purely indicative.
fi g. 5
fi g. 6
16
BOILER
Flow probe
HEAT
EXCHANGER
Burner
EXCHANGER
water heater probe
HEATING
water heater probe
BOILER
HEAT
Burner
hot water
cold water
hot water
cold water
HEATING