TROUBLESHOOTING
PROBLEM
Unit does not operate
Change light illuminated
For any problems not described here, please contact your local distributor for assistance.
SPECIFICATIONS
Model
HEPA 500 (F284-115V)
Weight
44 lbs. | 19.9 kg
Dimensions
24.6 × 26.2 × 18.2 in.
(D × W × H)
62.5 × 66.5 × 46.2 cm
Duct sizes
Intake: 12 in. Outlet: 8 in.
Power
3A, 115V, 60 Hz
Air movement
250–500 CFM
Filter system
Up to two prefilters and one HEPA filter.
Controls
On/Off switch, variable speed control knob
Power cord length
25 ft. | 7.63 m
Construction
Rotomolded polyethylene housing
Safety
UL/cUL listed
Specifications are subject to change without notice. Some values
may be approximate.
07-01489E F284-115V
CAUSE
1.
No power to machine
2.
Switch not turned on
3.
No power at supply outlet
4.
GFCI tripped
1.
Primary (HEPA) filter is full
2.
Air intake restricted by ducting
bends, kinks, or excessive
length
SOLUTION
1.
Plug in the unit; check power at outlet
2.
Turn on the switch
3.
Reset supply circuit breaker/GFCI
4.
Reset unit circuit breaker/GFCI
1.
Replace the HEPA filter
2.
Eliminate bends/kinks in ducting; reduce ducting
length.
6