− Contact 1-4 may be connected to a push button for a closure control that is separate from the COM96;
− Contact 1-8 is separate from COM96;
− Contact 1-9 is to be considered in line with the STOP set via the selector; therefore if it is not used it must be
jumped;
− Contact 1-29 is separate from COM96 and may be used to RESET the board;
− Contact 1-28 is not used to disconnect the locking, but to cancel the operating mode set by COM96. If
COM96 breaks down, and consequently the operating mode of the door becomes impossible to modify, keep
contact 1-28 closed for at least 10 seconds and the electric board will return to the bi-directional/total mode
with DISABLED automatic closure.
(Fig. 14).The automation opens with control 1-3 of the RADAR, it closes automatically with a 1-2 bridge; it
carries out safety with the photocells CEL. With connected and efficient batteries, in case of mains supply
interruption, the automation carries out its normal working. With batteries at the limit of charge, the automation
carries out the last opening motion. The switch between 1-9 carries out the normal working and with battery
ONLY WHEN IT IS CLOSED. The automation stops when the switch between 1-9 opens and no normal or
emergency function is carried out.
DIP 3 and 4 on ON, DIP 1 on OFF
6.PERIODIC MAINTENANCE - MUST BE EFFECTED BY QUALIFIED PERSONNEL -
Every 100,000 movements or every 4/6 months depending on use:
a) clean the wheel runners
b) check the tension of the driving belts
c) check all electric connections
d) check the fixing of the sensors
e) re-align the doors
f) clean the ground runners
g) clean sensors and photocells
h) check the battery charge by carrying out several emergency operations with the power supply switched off
i) check that the blocking device works correctly
j) if necessary regulate speed/power/breaking
k) check that all the safety devices work correctly
DECLARATION BY THE MANUFACTURER
(Directive 89/392/EEC, Annex II, sub B)
Manufacturer:
DITEC S.p.A.
Address:
via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY
Herewith declares that the automation system for sliding doors series GT
· is intended to be incorpored into machinery or to be assembled with other machinery to constitute machinery convered by Directive 89/
392/EEC, as amended;
· is in conformity with the provisions of the following other EEC directives:
Electromagnetic Compatibility Directive 89/336/EEC, as amended;
Low Voltage Directive 73/23/EEC, as amended;
and furthermore declares that it is not allowed to put the machinery into service until the machinery into which it is to be incorporated or of
which it is to be a component has been found and declared to be in conformity with the provisions of Directive 89/392/EEC and with
national implementing legislation.
Caronno Pertusella, 04/07/1997.
All right reserved
All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot
however take any responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative
purposes.
DIP 2 see note
21
E
Fermo Bressanini
(Chairman)
Tabla de contenido
loading

Este manual también es adecuado para:

GteGtvGts-lGts-p

Tabla de contenido