MOUNTING & WIRING
2
INFRARED SAFETY FIELD
OR
Activate the visible* spots to verify
the position of the IR-curtain.
Part of the detection field can be masked to reduce it.
The arrow position determines the width of the detection field.
Mounting
Detection
width
height
2.00 m
2.00 m
2.20 m
2.20 m
2.50 m
2.50 m
3.00 m
d max
3.50 m
d max
CLOSER
AWAY
If necessary, adjust the IR-curtain
angle (from -7° to 4°, default 0°).
* Visibility depends on external conditions. When spots are not visible, use the MRSP to locate the curtains.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should
always be smaller than 20 cm. The distance to the door leaf depends therefore on the thickness of the door leaf.
3.50 m
3,50 m
DIN 18650
BS 7036
3 m
3 m
2.50 m
2,50 m
2 m
2 m
d max = 2.5 m
d max = 2,5 m
12-24 V
AC-DC
*
*
**
* Output status when sensor is operational
** For compliance with EN 16005 and DIN 18650,
connection to door controller test output is required.
Always verify the actual detection field width
with a piece of paper and not the MRSP,
which detects the whole emitted field.
3.50 m
3,50 m
EN 16005
3 m
3 m
2,50 m
2.50 m
2 m
2 m
d max = 3 m
GREEN
POWER SUPPLY
BROWN
YELLOW
OPENING INPUT
WHITE
PINK
SAFETY INPUT
GREY
RED
TEST
OUTPUT
BLUE
The size of the detection field varies according to the
mounting height and the settings of the sensor.
The full door width must be covered.
DOOR
max.
9 cm**
Additional
adjustments
are possible by
LCD or remote
control
(see p. 5)