2.
When the first digit flashes, use the or ⊕ buttons to select the
preferred number.
3.
Press (↵) and repeat step 2 for all digits.
4.
Press-and-hold (↵) to quit code entry.
5.
From this point on you can only edit profiles after entering the
correct code
Security Lockout Notes:
You can 'turn off' the pass-code protection by 1
•
mode, entering the current code then setting the new code to '0000'
– All users now have full access to all program functions.
One code protects all profiles, not individual profiles.
•
If the Pass-code is lost or forgotten then the Master Reset function
•
will restore the factory defaults including erasing the pass-code
Master Reset.
To reset the unit it to factory settings, the following procedure can be used.
Press and hold ⊕ and (↵)
•
Whilst keeping ⊕ and (↵) depressed, switch the unit on
•
using
PLEASE NOTE: Use of the master reset will erase all stored programs.
12.
Once required changes have been made, press and hold (↵) for 3
seconds until the LCD stops flashing, to set the profile to memory and
exit setup mode. This operation can be actioned at any step while in
Setup Mode.
2.
Run & Manual Mode
1.
Turn on the unit by pressing the Power button.
2.
HCT start-up message and Software Rev # are momentarily displayed
before displaying last-used profile settings. Note: The unit may display
MRS if that was the last operational state.
3.
IMPORTANT ~ If "TC: TC1" is displayed on the panel (see Figure 4
above) ensure that the external thermocouple is suitably positioned in the
heat path. Neglecting to do this could result in premature heater failure
and possible heat damage to items in the heater path.
4.
Select the desired profile.
5.
When the chosen profile is shown, press (↵) to select the desired profile
6.
To start the profile, depress the (red) on the footswitch or (red) on
the hand-piece once
7.
As the profile runs you will see the current zone, time remaining, heater
value and temperature set point. Manual mode profiles will display
"Manual" and will not display time remaining.
8.
To quit the profile, simply depress the (red) on the footswitch or
(red) on the hand-piece. The profile will skip to the Cool-Down Zone.
During the cool zone, the profile can be restarted at any time by pressing
a red button on the footswitch or handpiece.
3.
Active Setup Mode
1.
Select Profile to be modified as per steps 1 3 above
2.
To activate Active Setup Mode press (↵) for 3 seconds then depress the
(red) on the footswitch or (red) button on the hand-piece once the
temperature in Z1 has started to flash
3.
Profile will start to run and 'SETUP' will be displayed on LCD
4.
To modify the current zone set-temperature use the ⊕ / buttons
5.
To increase the time of the current zone press and hold the (↵) button as
the zone ends. Instead of stepping onto the next zone the current zone
st
going into Program
6