The HCT-1000 has four operational modes. The operational modes are Setup, Run,
Manual and Active Setup. The Setup mode is for modifying system or profile
parameters. The Run mode is for operating the unit with a profile that uses four
zones of heating. The Manual mode is for operating the unit with a single zone of
heat and no time limit. The Active Setup mode allows for the changing of
parameters within a running profile.
1.
Setup Mode
1.
Press the Mode button (↵) once to start "P:" flashing
2.
Use the ⊕ / buttons to scroll through the profiles
3.
Press (↵) to select the desired profile
4.
Press and hold (↵) for 3 seconds to activate program mode (first
temperature in zone 1 will flash).
5.
Run Mode setup; proceed to step 3.1.6.1; Manual Mode setup
proceed to step 3.1.7.1.
6.
Run Mode Setup
1.
Use the ⊕ / buttons to change the temperature to the desired
value. (Note: continually pressing either the ⊕ or buttons for
5 seconds will change the count up/down in an accelerated
mode)
2.
When the value is set, press (↵) to move to the next parameter.
3.
Repeat steps 3.1.6.1 & 3.1.6.2 until profile is programmed.
Note: In the Cool-Down Zone you can only modify the Time
parameter
4.
Proceed to step 3.1.8.
7.
Manual Mode Setup
1.
Use the
desired value. (Note: continually pressing either the ⊕ or
buttons for 5 seconds will change the count up/down in an
accelerated mode)
2.
Set the Time for Zone 1 to a value greater than 300 seconds.
The display will now show the word MANUAL and Z2, Z3, Z4
will no longer be shown on the display.
Note: Manual mode profiles do not have a time requirement and
once activated will run until the profile is stopped. . However,
during the cool zone, the profile can be restarted at any time by
pressing ⊕ (or the red button on the footswitch or handpiece)
8.
Press (↵) to move to the next parameter. This is the HCT or MRS
option. Use ⊕ or to switch between HCT or MRS or press (↵) to
skip
9.
Press (↵) to move to the next parameter. This is the Internal or
External TC option. Use ⊕ or to switch between Int or TC1 or press
(↵) to skip.
Note: When TC1 is selected, TC1 becomes the master thermocouple
and provides feedback to the power supply.
10.
Press (↵) to move to the next parameter. This is the Airflow option
(AF). Use ⊕ to increase or to decrease the airflow. The range is
adjustable from 1-10. Note: The Air Pump will turn on while adjusting
the Airflow. Press (↵) to skip.
↵
11.
Press (
) to move to the next parameter. This is the Security Lockout
function. HCT-1000 systems are supplied with a lockout feature to
prevent operators from editing profiles etc. To activate this function, a 4
digit number must be entered within a program setup as explained
below.If the pass code is set at 0000 the programs are not protected.
1.
When C: 0000 appears on the screen, you can select a 4 digit pass
code.
/ buttons to change the temperature to the
⊕
5