Cleaning Accessories - EdilKamin MIMI’ Instalación Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Cleaning the smoke duct
• With the stove off and cold, move the cleaning rods energetically (see page 34). Remove the lower cast iron front panel (fig. D), the
silicone stopper (fig. E) and vacuum the residue (fig. F).
The amount of residue will depend on the type of fuel and system.
Failure to carry out this cleaning procedure may cause the thermal stove to block.
Once the procedure is implemented, ensure that the inspection hatch is closed properly.
fig. D
Seasonal cleaning (implemented by the dealer)
After 2500 kg of pellets have been consumed, 'MAINTENANCE??' will appear on the display.
The thermal stove does NOT block but signals the need for the maintenance procedure to be implemented by a DEALER.
Before performing any maintenance, disconnect the appliance from the mains.
Upon the 1st ignition, the authorised DEALER will provide the thermal stove maintenance manual, which contains the
operations to be carried out during the seasonal cleaning procedure.
Clean the stove internally and externally
Carefully clean the heat exchange tubes
Carefully clean and remove dirt from the combustion chamber and the relative compartment
Clean the motors, verify mechanical and clam loosening
Clean smoke channel (replace seals on pipes) and smoke extraction fan chamber
Check the expansion tank
Check and clean the circulator
Check the sensors
Check and if necessary replace the clock battery on the control board
Clean, inspect and scrape any residue from the ignition resistance compartment and if necessary, replace it
Clean/check the Synoptic Panel
Visually inspect the electrical wires, connections and power cable
Clean the pellet hopper and check loosening of the feed screw - gear motor assembly
Check and if necessary replace the door seal
Functionality test: load the feed screw, ignite, let it run for 10 minutes and shutdown
If maintenance if not implemented, the warranty will be rendered null and void.
If the thermal stove is used very often, it is recommended to clean the smoke channel every 3 months.
When maintenance is implemented in the smoke channel, consider UNI 10847/2000 Individual chimney installations for generators
running on liquid and solid fuel. Maintenance and control.

CLEANING ACCESSORIES

GlassKamin
(code 155240)
Used for cleaning the
ceramic glass
MAINTENANCE
fig. E
35
fig. F
Ash vacuum cleaner
(code 275400)
User for cleaning the
hearth
Tabla de contenido
loading

Tabla de contenido