Kenmore 148.16656011 Manual De Uso Y Cuidado página 27

Parilla a gas de propane liquido
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Problem
Low heat with the
knob in "HI"
position
Low heat, natural
gas
Low heat,
LP gas
Sudden drop in
gas flow or low
flame
Possible Cause
1. Low heat is found in natural
gas models.
2. Ports are blocked.
3. LP tank has run out.
Gas pressure is significantly
affected by gas line and
length of gas line from house
gas line.
The propane regulator
assembly incorporates an
excess flow device designed
to supply the grill with
sufficient gas flow. Rapid
changes in pressure can
trigger the excess flow device,
providing a low flame
and low temperature.
1. Out of gas.
2. Excess flow valve tripped.
3. Vapor lock at coupling
nut/LP cylinder connection.
Corrective Action
1. This model is set for 7 in. natural
gas usage. Please check your
natural gas supply system to
have correct gas pressure.
Regulator is not needed for NG
model.
Check the orifice if you installed
NG nozzles.
2. Clear ports of any obstructions.
3. Refill the LP tank.
Check your gas line and make
corrections by following the chart
below.
From House to Grill
Distance
Up to 25 ft.
26 -50 ft.
51 -100 ft.
Please follow these instructions:
1. Make sure all burners are "OFF".
2. Open the tank valve and wait 5
minutes.
3. Light the burner one at a time
following the lighting instructions
listed on the door liner
1. Check for gas in LP cylinder.
2. Turn off knobs, wait 30 seconds
and light grill. If flames are still
low, turn off knobs and LP
cylinder valve. Disconnect
regulator. Reconnect regulator
and leak test. Turn on LP cylinder
valve, wait 30 seconds and then
light grill.
3. Turn off knobs and LP cylinder
valve. Disconnect coupling nut
from cylinder. Reconnect and
retry.
27
Tubing Size
3/8 in. diameter
1/2 in. diameter
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido