Parameter
0
Boost time
Programme P1
1
time
Programme P2
2
time
Type of
3
programme
Setpoint tempera-
4
ture calibration
Room temperature
5
calibration
Type of energy
6
source
7
Default display
Version number
8
display and reset
Quitting parameter
end
settings display
* The remote control parameters are set according to the power supply of your towel radiator (hot
water or electricity). We advise against modifying the default value.
40
description
Adjustable from 15 to 120
minutes in 15-minute
increments
Adjustable from 15 to 120
minutes in 15-minute
increments
Adjustable from 15 to 120
minutes in 15-minute
increments
Value 0 (blower only), 1
(radiator on boost) or 2
(radiator on boost + blower)
Adjustable between -5.0°C
to 5.0°C in 0.5°C increments
Not available on this model
NEVER modify! *
Value 0 (time) or 1 (setpoint
temperature)
Reset to factory settings.
The time will have to be
re-set.
Quit parameter setting menu
default setting
Setting
Press the
30 minutes
key
- If parameter 3 = 0
or 2: 30 minutes
Press the
key
- If parameter 3 = 1:
60 minutes
- If parameter 3 = 0
or 2: 30 minutes
Press the
key
- If parameter 3 = 1:
60 minutes
Press the
1
key
Press the
0,0°C
key
--
1
Press the
1
key
Press the
for 10 seconds
Press
+
-
or
+
-
or
+
-
or
+
-
or
+
-
or
+
-
or
+
key
P2