Technical Data - SFA SANI BEST Pro Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
UK
The boxed numbers (e.g.
Fully illustrated step by step instructions are
downloadable on www.saniflo.co.uk
1
DESCRIPTION
This pump/macerator has been designed to pump away the
waste from a WC and the sanitary appliances mentioned in fig
. SANIBEST Pro
is a robust machine which is capable
®
1
of handling occasional sanitary article accidentally flushed
down the WC. Installed and used correctly, SANIBEST Pro
will give consistent and reliable service.
Please note the following warning signs:
«
» Possible danger to personnel,
«
» Warning of possible electrical hazard,
«
» Instructions for use only by qualified professionals,
«WARNING» This is a general warning that failure to
follow instructions could result in poor functioning
of the unit.
2
LIST OF ACCESSORIES INCLUDED
3
DIMENSIONS
4

TECHNICAL DATA

Application
Type
Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption5 A
Electric Class
Degree of protection
Net Weight
WARNING:
Only installations conforming to the above
specifications are acceptable.
5
PERFORMANCE CURVE
6
VERTICAL/HORIZONTAL PUMPING
COMBINATIONS
7
INSTALLATION
WARNING:
The unit must be connected to a WC pan with
horizontal outlet spigot conforming to EN33 or EN 37 norms.
The SANIBEST should be installed so that it is accessible
for possible maintenance
The macerator has fastenings preventing it turning or from
floating.
CONNECTION TO A WC
7a
1 - Pull flexible sleeve over the pan of the machine.
2 - Fix with the Ty-Rap supplied.
3 - Slip the collar around the cuff then slip the cuff
around the basin exit.
4 - Position the collar at the extremity of the cuff then
tighten with a screwdriver.
8710 127 SANIBEST PRO NOTICE-exe.indd 8
) refer to the explanatory diagrams and the circled numbers (e.g. 7a ) refer to the scatter diagram on the last page.
1
1 WC + + shower
+ bidet + washbasin
B85
max. 7 m
220-240 V
50 Hz
1100 W
I
IP44
10 kg
CONNECTION OF THE DISCHARGE PIPEWORK
7b
1 - Use the elbow and the stepped sleeve
2 - Insert the sleeve on the elbow. Fix it in place with a
collar
.
D
3 - Orient the assembly as required and push it well into
the black rubber pipe 7 . Fix the base of the elbow in
place with a collar
4 - Cut off the end of the sleeve, if necessary, to suit the
diameter of the discharge pipe and use a collar
®
5 - We advise installing a drain valve at the low point to
facilitate maintenance.
6 - To avoid siphoning, fit an anti-syphon valve (capable of
withstanding about 10 psi pressure) at the high point, or
increase the diameter of the horizontal pipe.
• All horizontal piperuns require a 1:100 fall.
• If a vertical lift is required, this must be installed at the
start of piperun and a 1:100 fall given to the pipe from
the high point to the drain.
• All bends should be smooth/slow (eg pulled bens or
2 x 45 degree bends together). Do not use 90° elbows.
• If the horizontal piperun exceeds about 10 metres, increase
the size from 22 mm to 32 mm from that point onwards.
CONNECTION OF THE OTHER SANITARY APPLIANCES
7c
1 - To connect to the side entries of the case, use the
rubber connector
2 - Plug the unused inlet with blanking plug
greasing the joint.
WARNING:
Ensure when connecting a shower to
SANIBEST Pro
that the underside of the shower tray is
®
raised by at least 15cm from the floor.
CONNECTION OF A WASHBASIN
7d
The washbasin can be connected in two ways.
To one of the side inlets (see
Or to the raised inlet that can be cut open on the cover.
To do so:
• Cut off the top of the raised inlet with a saw.
• Do not leave any sharp angles on the edge of the cut.
Remove any burrs.
• Insert a sleeve
in the hole in the cover.
C
• Insert the Ø 32 mm waste pipe from the washbasin
into the sleeve (clips
VENTING
7e
SANIBEST Pro
is fitted with an active carbon filter, and
®
requires no external venting.
EXAMPLE OF SANIBEST Pro
7f
ELECTRICAL CONNECTION
7g
The electrical installation should be carried by a
qualified person and conform to BS 7671 1992
requirements for electrical installation.
The unit requires a 220/240V single phase AC 50 Hz supply
(UK specification). Do not connect the unit to a conventio-
nal plug and socket.
The unit should be connected to a fully earthed electrical
supply (class 1). It must be wired into an unswitched fused
fixed wiring connector protected by a 5 amp fuse and a
residual current detector (10 A minimum). This connection
must be used exclusively for supplying the unit.
The unit should be sited at least 60 cm away from any
shower tray.
8
.
B
.
D
. Secure with clips
and
C
D
after
F
)
7c
supplied).
D
' INSTALLATION
®
or
.
E
J
.
E
14/09/10 17:07
Tabla de contenido
loading

Tabla de contenido