Potentiometer Adjustment - Erreka VIVO-M201 Guía Rápida De Instalación Y Programación

Ocultar thumbs Ver también para VIVO-M201:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

DIP
Modes and functions
DIP1
DIP2
Advance warning
DIP3
Opening mode
Automatic or step-by-step mode
DIP4
(for pedestrian and total operation)
Reverse impulse /
DIP5
close impulse
Automatic mode optional
DIP6
(only if DIP4 = ON)
Maintaining hydraulic pressure
DIP7
(for hydraulic operators only)
Soft stop (only for operators
DIP8
without mechanical absorber)
DIP9
No function
DIP10 No function
P1 P2 P3
P4 P5 P6
ST1
FT1
ST2
FT2
12
Function and mode selection using SW2 (DIP1 = OFF)
Option
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF

Potentiometer adjustment

T.D (lapse between leaves during closing): adjust the time which passes
between the start of closing of one leaf and the other. The opening lapse time
is not adjustable.
T.LG (garage light time): if the garage lighting circuit has been connected to
the control board, regulate the time which the lights shall remain on using T.LG.
T.E. (gate open standby time): if automatic functioning mode has been
programmed (DIP4=ON), set T.E. to adjust standby time with the gate open
(before automatic closing begins).
P.M (motor torque): use P.M. to adjust the maximum operator power value.
• Hydraulic operators: set P.M. at the maximum value.
• Electromechanical operators: set P.M at the minimum value possible,
FCA2 COM FCC2
SCA
compatible with the proper operation of the gate.
Adjust the torque to respect the maximum closing thrusts set out in
Standard EN12453:2000. Make the measurements as described in
P15 P14 P16
P7 P8
P11 P12
P22
Standard EN 12445:2000.
24Va
FCA1
FCC1
STOP
LOCK
P176M
Effect
the flashing light comes on and the operation begins after a 3 second
warning
the flashing light comes on and the operation begins immediately
step-by-step opening (the gate halts if a key device is enabled
during opening, and closes if enabled again)
collective opening (the control board does not obey the key
commands during opening)
automatic mode (the gate closes automatically after standby time
has passed, which is adjusted using T.E.). Standby time restarts if the
photocell is enabled.
step-by-step mode (the gate only closes when receiving the key
command)
recede impulse enabled. If soft stop is selected (DIP8=ON), a close
impulse is also carried out
close and recede impulse disabled
during standby, the gate obeys the key commands (can be closed
before standby time finishes)
the gate cannot be closed until standby time finishes; a key command
will cause standby time to restart
every half an hour it carries out a close impulse in order to maintain
hydraulic pressure
maintain pressure disabled
the leaves reduce their speed before reaching the stopper
the leaves reach the stopper at high speed
place always in OFF
place always in OFF
Tabla de contenido
loading

Este manual también es adecuado para:

Vivo-m201m

Tabla de contenido