Potentiometer Adjustment - Erreka PUMA Guía Rápida De Instalación

Ocultar thumbs Ver también para PUMA:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
DIP
Modes and functions
DIP1
DIP2
Advance warning
DIP3
Opening mode
Automatic or step-by-step mode
DIP4
(for pedestrian and total operation)
Automatic mode optional
DIP5
(only if DIP4 = ON)
DIP6
No function
DIP7
Encoder
DIP8
Slowdown
DIP9
Limit switches configuration
Type of deceleration
DIP10
(only if DIP8 = ON)
12
Function and mode selection using SW2 (DIP1 = OFF)
Option
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF

Potentiometer adjustment

Effect
the flashing light comes on and the operation begins after a 3
second warning
the flashing light comes on and the operation begins
immediately
step-by-step opening (the gate halts if a key command is
activated during opening, and closes if activated again)
collective opening (the control board does not obey the key
commands during opening)
automatic mode (the gate closes automatically after the
standby time has passed, which is adjusted using T.E.). A key
command (or photocell activation) causes standby time to
restart
step-by-step mode (the gate only closes when receiving the key
command)
during standby, the gate obeys the key commands (this can be
closed before standby time finishes)
the gate cannot be closed until standby time finishes; a key
command will cause standby time to restart
place always in OFF
encoder enabled
encoder disabled
the gate reduces its speed before reaching the stopper
the gate reaches the stopper at high speed
gate which opens to the right
gate which opens to the left
progressive deceleration (deceleration ramp 1.5 seconds)
sudden deceleration (no deceleration ramp)
T.E (Standby Time): open gate standby time
If automatic functioning mode has been programmed
(DIP4=ON), set T.E. to adjust standby time with the gate
open (before automatic closing begins).
• Minimum value: 0 seconds; maximum value: 90
seconds
P.M (Torque Regulator): motor torque
Use P.M. to adjust the maximum motor power value.
Adjust the torque to respect the maximum closing
thrusts set out in Standard EN12453:2000. Make
the measurements as described in Standard EN
12445:2000.