5. Thermal imager and DMM opertion

5.1. Thermal imager basics

In the Thermal imaging and DMM mode. User can mearsure a targeted surface's
temperature and user can use Mutimeter at the same time, the measured result will
display under the themal image.
• Press the red "IR" button to open the Thermal Imager. In Fig5-1 the thermal image is set
to color palette IRON. Select other palettes in the Menu Settings.
• Open the protective lens cover on the back of the meter.
12
5
6
7
8
9
10
11
1- The Battery capacity indicator.
2- The currently selected Emissivity value. Use the Thermal Settings Menu to change the
emissivity value.
3- The temperature unit icon, Use the Thermal Settings Menu to select "
4- Current time Display
5- Center cross of the Thermal imager Temperture Measurement, represents the center
spot temperature of the scene.
22
EN
34
17
16
15
14
13
12
o
o
C",
F,K.
EN
6 - Highest temperature spot of the Thermal imager Temperture Measurement, represents
the highest spot temperature of the scene.
7 - Minimum temperature spot of the Thermal imager Temperture Measurement, the
Minimumspot temperature of the scene.
8 - Current scene ot theThermal image frame
9 - Range icon of the meter
10- Max soft button
11- REL soft button
12- PEAK soft button
13- DMM measurement is shown below the thermal image.
14- Unit of the meter
15- Lowest reading measured in the current frame
16- The Thermal scale shows the range color for thermal images, The lighter the color, the
warmer the temperature; The darker the color, the cooler the temperature.
17- Highest reading measured in the current frame.

5.2. Using the thermal imager

For basic operation follow these steps:
1. Set the function switch to any position.
2. Press the "IR" button to switch the thermal imager ON. Target the object by the
thermal imager len.
3. The display will show the temperature measurement in the upper left hand corner for
the targeted area along with the currently selected emissivity value.
4. In the Thermal imaging mode, the laser pointer and dispay cross hairs can be used to
assist in targeting. These tools can be switched ON or OFF in the Setting menu.
5. In the Thermal imaging mode, the highest temperature will auto marked by a red cross,
and the lowest temperature will auto marked by a blue cross, the two spots can be
switched ON or OFF in the Setting menu.
6. In the Thermal imaging mode, the meter continues to operate normally as a Multimeter
allowing any of the electrical functions to be used.
7. Press the HOLD button to hold the thermal image frame, then long press the HOLD
button, you will capture the screen and save a bitmap with measure data into SD card,
the saved bitmap later can be analysed by the PC software or smartphone APPs.
KMIR-01
23
Tabla de contenido